杂乱
计算机科学
滤波器(信号处理)
去相关
声学
人工智能
多普勒效应
心跳
计算机视觉
物理
雷达
电信
计算机安全
天文
作者
Yizhou Huang,Xufei Chen,Emilia Bădescu,M.P.J. Kuenen,Odile Bonnefous,Massimo Mischi
出处
期刊:Ultrasonics
[Elsevier]
日期:2024-03-26
卷期号:140: 107307-107307
被引量:2
标识
DOI:10.1016/j.ultras.2024.107307
摘要
With the development of advanced clutter-filtering techniques by singular value decomposition (SVD) and leveraging favorable acquisition settings such as open-chest imaging by a linear high-frequency probe and plane waves, several studies have shown the feasibility of cardiac flow measurements during the entire cardiac cycle, ranging from coronary flow to myocardial perfusion. When applying these techniques in a routine clinical setting, using transthoracic ultrasound imaging, new challenges emerge. Firstly, a smaller aperture is needed that can fit between ribs. Consequently, diverging waves are employed instead of plane waves to achieve an adequate field of view. Secondly, to ensure imaging at a larger depth, the maximum pulse repetition frequency has to be reduced. Lastly, in comparison to the open-chest scenario, tissue motion induced by the heartbeat is significantly stronger. The latter complicates substantially the distinction between clutter and blood signals. This study investigates a strategy to overcome these challenges by diverging wave imaging with an optimal number of tilt angles, in combination with dedicated clutter-filtering techniques. In particular, a novel, adaptive, higher-order SVD (HOSVD) clutter filter, which utilizes spatial, temporal, and angular information of the received ultrasound signals, is proposed to enhance clutter and blood separation. When non-negligible tissue motion is present, using fewer tilt angles not only reduces the decorrelation between the received waveforms but also allows for collecting more temporal samples at a given ensemble duration, contributing to improved Doppler performance. The addition of a third angular dimension enables the application of HOSVD, providing greater flexibility in selecting blood separation thresholds from a 3-D tensor. This differs from the conventional threshold selection method in a 2-D spatiotemporal space using SVD. Exhaustive threshold search has shown a significant improvement in Contrast and Contrast-to-Noise ratio for Power Doppler images filtered with HOSVD compared to the SVD-based clutter filter. With the improved settings, the obtained Power Doppler images show the feasibility of measuring coronary flow under the influence of non-negligible tissue motion in both in vitro and ex vivo.
科研通智能强力驱动
Strongly Powered by AbleSci AI