功率因数
控制理论(社会学)
前馈
电感器
电压
计算机科学
电子工程
工程类
电气工程
控制(管理)
控制工程
人工智能
作者
Ji Zhang,Yan Li,Fangyi Wei,Yi Tian
标识
DOI:10.1109/cieec58067.2023.10167182
摘要
Continuous conduction mode (CCM) Totem Pole bridgeless power factor correction (PFC) converters with the traditional average current control method cannot achieve unity power factor at light loads due to the limited gain of PI controller at low frequencies. In this paper, an error current analysis method is proposed, which divides the steady-state error between the reference current and the inductor current under PI control into two parts: tracking error and disturbance error. It shows that the disturbance error is the main reason why unity power factor cannot be achieved. The steady-state error is eliminated through the inductor voltage drop feedforward and the input voltage feedforward, and the capacitive current caused by the EMI filter is also compensated, so that unity power factor can still be maintained at ultra-light load. Finally, a simulation circuit of the Totem Pole bridgeless PFC is built to verify the correctness of the theory and the effectiveness of the control method.
科研通智能强力驱动
Strongly Powered by AbleSci AI