Is the airway volume being correctly analyzed?

组内相关 金标准(测试) 图基射程试验 锥束ct 核医学 标准差 体积热力学 相关系数 数学 气道 医学 统计 计算机断层摄影术 再现性 放射科 外科 物理 量子力学
作者
Matheus Alves,Carolina Baratieri,Cláudia Trindade Mattos,Daniel Paludo Brunetto,Ricardo da Cunha Fontes,Jorge Roberto Lopes dos Santos,Antônio Carlos de Oliveira Ruellas
出处
期刊:American Journal of Orthodontics and Dentofacial Orthopedics [Elsevier]
卷期号:141 (5): 657-661 被引量:67
标识
DOI:10.1016/j.ajodo.2011.11.019
摘要

The aim of the study was to determine the most accurate threshold value for airway volume quantification based on specific experimental conditions.Ten scans from the airway prototype were obtained by using cone-beam computed tomography. The volume from each scan was measured with 8 values (25, 50, 70, 71, 72, 73, 74, and 75) of the threshold tool from the Dolphin software (Dolphin Imaging and Management Solutions, Chatsworth, Calif). The gold standard method used was the actual volume of the airway prototype, which was compared with the different threshold values. An intraclass correlation coefficient test was applied to evaluate the intraexaminer calibration and verify differences among the airway volumes measured in all cone-beam computed tomography scans. Analysis of variance with the Tukey post-hoc test was used to compare differences among the measurements with different threshold values with the gold standard.The intraexaminer reliability was confirmed by the intraclass correlation coefficient, which was ≥0.99. The intraclass correlation coefficient used to verify the differences among the airway volume measurements in all cone-beam computed tomography scans was ≥0.98, showing that they were comparable. Analysis of variance and the Tukey post-hoc test showed that the volumes measured with the threshold values of the 25 and 50 filters had statistically significant differences from the gold standard. However, volumes measured with the threshold values of the 70, 71, 72, 73, 74, and 75 showed no statistically significant differences from the gold standard and among them.In our study for the cone-beam machine and the acquisition parameters used, the threshold value of the 73 used in Dolphin 3D software was the most accurate to measure airway volume, but the threshold values of the 70, 71, 72, 74, and 75 had no statistically significant differences compared with the gold standard, showing they are also reliable.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
小邓完成签到 ,获得积分10
2秒前
肖肖完成签到,获得积分10
3秒前
3秒前
znlion发布了新的文献求助10
3秒前
慕青应助忭博士采纳,获得10
6秒前
爱学习发布了新的文献求助10
8秒前
科研通AI2S应助小白果果采纳,获得10
10秒前
11秒前
11秒前
ayitime发布了新的文献求助10
11秒前
11秒前
znlion完成签到,获得积分10
12秒前
13秒前
smy发布了新的文献求助30
16秒前
17秒前
18秒前
23秒前
FashionBoy应助lighta0采纳,获得30
24秒前
忭博士发布了新的文献求助10
29秒前
李健应助TTD采纳,获得10
29秒前
36秒前
ding应助辛勤香岚采纳,获得10
37秒前
研友_LX66qZ完成签到,获得积分10
37秒前
WBH36323完成签到 ,获得积分10
38秒前
碧蓝的秋莲完成签到,获得积分10
41秒前
打屁飞完成签到,获得积分10
45秒前
haofan17完成签到,获得积分10
49秒前
jimoon完成签到,获得积分10
50秒前
程南完成签到,获得积分10
57秒前
yyl完成签到 ,获得积分10
59秒前
59秒前
sugarxy应助oleskarabach采纳,获得10
1分钟前
1分钟前
1分钟前
樘樘完成签到,获得积分10
1分钟前
1分钟前
活力毛豆完成签到 ,获得积分10
1分钟前
科研通AI2S应助步云乱采纳,获得10
1分钟前
陈冲发布了新的文献求助10
1分钟前
living笑白完成签到,获得积分10
1分钟前
高分求助中
LNG地下式貯槽指針(JGA指-107) 1000
LNG地上式貯槽指針 (JGA指 ; 108) 1000
Preparation and Characterization of Five Amino-Modified Hyper-Crosslinked Polymers and Performance Evaluation for Aged Transformer Oil Reclamation 700
Operative Techniques in Pediatric Orthopaedic Surgery 510
How Stories Change Us A Developmental Science of Stories from Fiction and Real Life 500
九经直音韵母研究 500
Full waveform acoustic data processing 500
热门求助领域 (近24小时)
化学 医学 材料科学 生物 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 基因 遗传学 物理化学 催化作用 免疫学 细胞生物学 电极
热门帖子
关注 科研通微信公众号,转发送积分 2929742
求助须知:如何正确求助?哪些是违规求助? 2581046
关于积分的说明 6961137
捐赠科研通 2229951
什么是DOI,文献DOI怎么找? 1184808
版权声明 589534
科研通“疑难数据库(出版商)”最低求助积分说明 579903