喷油器
过冷
机械
雷诺数
冷凝
湍流
蒸汽爆炸
压缩流体
材料科学
热力学
传质
喷射(流体)
渗透(战争)
航程(航空)
化学
传热
复合材料
物理
核物理学
工程类
运筹学
作者
P. J. Kerney,G. M. Faeth,Donald R. Olson
出处
期刊:Aiche Journal
[Wiley]
日期:1972-05-01
卷期号:18 (3): 548-553
被引量:194
标识
DOI:10.1002/aic.690180314
摘要
Abstract An experimental investigation was made of the lenght of the turbulent vapor cavity formed by a steam jet discharging into a subcooled liquid water both. The experiments considered both constant area and convergent‐divergent steam injectors of various external geometries. The tests were conducted with the bath at atmospheric pressure, bath temperatures in the range 301–358K, injector exit diameters in the range 0.00040–0.0112 m, for choked injector flows having mass velocities in the range 332–2050 kg/m 2. s. These conditions yielded injector exit Reynolds numbers from 2 to 150 × 10 4 . Over this range a correlation was developed to yield the length of the vapor cavity as a function of the injector diameter, exit mass velocity, and a driving potential for the condensation process. The heat transfer coefficients for this condensation process were found to be significantly greater than those encountered in turbulent film condensation processes in the vicinity of tubes and walls.
科研通智能强力驱动
Strongly Powered by AbleSci AI