流出物
絮凝作用
化学需氧量
聚电解质
总悬浮物
污水处理
化学
制浆造纸工业
废水
活性污泥
悬浮物
浊度
环境化学
环境科学
环境工程
生物
生态学
有机化学
工程类
聚合物
作者
Cudjoe Shamika,Banerjee Goutam,Cooper Vincent
标识
DOI:10.1186/s13036-023-00344-w
摘要
Abstract Background Effluents from Food Services Establishments (FSEs) contain primarily Fats, Oil and Grease (FOG) which severely impact on sewers and the environment when released in high concentrations. In Trinidad & Tobago, it is estimated that approximately 231,304 kg/day of unaccounted for FOG bearing wastewaters from FSEs, are released into the environment with no viable treatment in the country. This research explored the optimization of physico-chemical processes for the treatment of FOGs for subsequent release into sewers. Results Bench-scale studies analysed the characteristics of FSE’s effluents from three popular sources, conducted the treatment of these effluents using Jar Tests, and subsequently confirm results via a pilot plant study. Characterization showed the mean concentration of the parameters examined to be; FOG (511 mg/l ± 116 mg/l), Suspended Solids (446 mg/l ± 146 mg/l), Chemical Oxygen Demand (2229 mg/l ± 963 mg/l) and pH (6 ± 0.3). Jar Tests were conducted using Poly-aluminium Chloride (PACl) as coagulant, anionic and cationic polyelectrolytes as flocculant aids with suitable pH adjustments of samples to determine the isoelectric point for the coagulant. Effluent results showed FOG removal levels of 99.9% and final effluent concentration of 0.17 mg/l. This was attained using PACl concentration of 250 mg/l, a 0.1% low cationic polyelectrolyte (CP 1154) at 4 mg/l with the pH of sample adjusted to 8. The pilot plant achieved a 97.4% removal of FOG (residual of 16.8 mg/l) using the same coagulant dosing, and pH value, but increasing the strength of the flocculant aid to 0.1% medium cationic (CP1156) at 5 mg/l. Conclusion Experimentation showed high concentrations of emulsified FOG can be efficiently removed to levels below the permissible requirements (20 mg/l) for entry into sewer systems in Trinidad and Tobago using coagulation, flocculation and sedimentation techniques. Pilot scale study also revealed that a higher strength and/or dose of the cationic polyelectrolyte and increased times in primary and final tanks were required to attain the desired results as in the bench level study, where equipment limitations in the flocculation tank were faced. This is in alignment with theory where factors critical for agglomeration is equipment type and density charge. It is, concluded that the optimum combination of chemicals and the respective dosages attained at the bench level study should prove effective should the right equipment be made available.
科研通智能强力驱动
Strongly Powered by AbleSci AI