组内相关
等级间信度
标准误差
可靠性(半导体)
内部评级可靠性
收敛有效性
协议限制
标准效度
心理学
物理疗法
物理医学与康复
医学
统计
心理测量学
数学
评定量表
结构效度
临床心理学
内部一致性
发展心理学
核医学
功率(物理)
物理
量子力学
作者
L. Liz,Tuyra Francisca Castro e Silva,Stella Maris Michaelsen
出处
期刊:Physical therapy
[Oxford University Press]
日期:2023-05-31
卷期号:103 (8)
被引量:7
摘要
The objective of this study was to investigate the validity, reliability, and measurement error of the Fugl-Meyer Assessment (FMA) when it was remotely administered by videoconferencing (Tele-FMA) and to describe barriers to remote administration of the FMA.Forty-five participants who had strokes and had a smartphone or laptop computer with a camera and internet access were included. An in-person assessment was compared with a remote assessment in 11 participants, and 34 participants completed only the remote assessment. Rater 1 (R1) remotely administered, recorded, and scored the items of the FMA, after which the recording was forwarded to be scored by Rater 2. At least 7 days later, R1 rated the videorecording of the remote assessment a second time for the evaluation of intrarater reliability. In-person assessment was completed by R1 at the participant's home. Criterion validity was analyzed using the Bland-Altman limits of agreement, and convergent validity was analyzed using Spearman correlation coefficient. The intrarater and interrater reliability was analyzed using the intraclass correlation coefficient, and individual items were analyzed using the weighted kappa. The standard error of measurement and minimal detectable change were calculated to evaluate the measurement error.Bland-Altman plots showed adequate agreement of in-person FMA and tele-FMA. A moderate positive correlation was found between Tele-FMA lower extremity (LE) scores and step test results, and a strong positive correlation was found between Tele-FMA-upper extremity (UE) and Stroke Impact Scale hand function domain. Significant and excellent (0.96 ≤ ICC ≤ 0.99) interrater and intrarater reliabilities of the Tele-FMA, Tele-FMA-UE, and tele-FMA-LE were found. Regarding the individual items, most showed excellent reliability (weighted kappa > 0.70). The standard error of measurement for both reliabilities was small (≤3.1 points). The minimal detectable change with 95% CI for both the Tele-FMA and Tele-FMA-UE was 2.5 points, whereas it was 1.3 points for the Tele-FMA-LE.Tele-FMA has excellent intrarater and interrater reliability and should be considered as a valid measurement.The FMA is widely used in clinical practice. However, the measurement properties of the remote version applied by videoconferencing were unknown. This study's results demonstrate the validity and reliability of the Tele-FMA for assessing poststroke motor impairment remotely via videoconferencing. The Tele-FMA may be used to implement telerehabilitation in clinical practice.
科研通智能强力驱动
Strongly Powered by AbleSci AI