医学
心肺复苏术
通风(建筑)
复苏
气道
麻醉
心脏病学
内科学
机械工程
工程类
作者
Ahamed H. Idris,Elisabete Aramendi,Brian G. Leroux,Xabier Jaureguibeitia,Betty Yang,Sarah Shaver,Mary P. Chang,Tom Rea,Peter J. Kudenchuk,Jim Christenson,Christian Vaillancourt,Clifton W. Callaway,David D Salcido,Jonas Carson,Jennifer Blackwood,Henry E. Wang
出处
期刊:Circulation
[Ovid Technologies (Wolters Kluwer)]
日期:2023-12-05
卷期号:148 (23): 1847-1856
被引量:11
标识
DOI:10.1161/circulationaha.123.065561
摘要
BACKGROUND: Few studies have measured ventilation during early cardiopulmonary resuscitation (CPR) before advanced airway placement. Resuscitation guidelines recommend pauses after every 30 chest compressions to deliver ventilations. The effectiveness of bag-valve-mask ventilation delivered during the pause in chest compressions is unknown. We sought to determine: (1) the incidence of lung inflation with bag-valve-mask ventilation during 30:2 CPR; and (2) the association of ventilation with outcomes after out-of-hospital cardiac arrest. METHODS: We studied patients with out-of-hospital cardiac arrest from 6 sites of the Resuscitation Outcomes Consortium CCC study (Trial of Continuous Compressions versus Standard CPR in Patients with Out-of-Hospital Cardiac Arrest). We analyzed patients assigned to the 30:2 CPR arm with ≥2 minutes of thoracic bioimpedance signal recorded with a cardiac defibrillator/monitor. Detectable ventilation waveforms were defined as having a bioimpedance amplitude ≥0.5 Ω (corresponding to ≥250 mL V T ) and a duration ≥1 s. We defined a chest compression pause as a 3- to 15-s break in chest compressions. We compared the incidence of ventilation and outcomes in 2 groups: patients with ventilation waveforms in <50% of pauses (group 1) versus those with waveforms in ≥50% of pauses (group 2). RESULTS: Among 1976 patients, the mean age was 65 years; 66% were male. From the start of chest compressions until advanced airway placement, mean±SD duration of 30:2 CPR was 9.8±4.9 minutes. During this period, we identified 26 861 pauses in chest compressions; 60% of patients had ventilation waveforms in <50% of pauses (group 1, n=1177), and 40% had waveforms in ≥50% of pauses (group 2, n=799). Group 1 had a median of 12 pauses and 2 ventilations per patient versus group 2, which had 12 pauses and 12 ventilations per patient. Group 2 had higher rates of prehospital return of spontaneous circulation (40.7% versus 25.2%; P <0.0001), survival to hospital discharge (13.5% versus 4.1%; P <0.0001), and survival with favorable neurological outcome (10.6% versus 2.4%; P <0.0001). These associations persisted after adjustment for confounders. CONCLUSIONS: In this study, lung inflation occurred infrequently with bag-valve-mask ventilation during 30:2 CPR. Lung inflation in ≥50% of pauses was associated with improved return of spontaneous circulation, survival, and survival with favorable neurological outcome.
科研通智能强力驱动
Strongly Powered by AbleSci AI