Andrew Lam,William A. Douthwaite
标识
DOI:10.1046/j.1475-1313.1996.95000151.x
摘要
Summary A corneal topography study was carried out on Hong Kong Chinese subjects using a modified keratometer. The Chinese corneal topography measured by this modified keratometer was similar to other studies using the Wesley–Jessen Photo Electronic Keratoscopy (PEK) System 2000. The mean p ‐values along the horizontal meridian and the vertical meridian were 0.82 and 0.87, respectively. A negative correlation was found between the p ‐value and the central corneal radius along the horizontal meridian which may indicate that a steeper central cornea will have a greater p ‐value. However, the correlation coefficient of 0.56 was not too certain for this conclusion to be drawn. A difference of 0.04 was found between the horizontal p ‐value and the vertical p ‐value, which may be a result of the tight lid tension along the vertical meridian. This modified keratometer can be considered as an inexpensive instrument for the study of corneal topography.