已入深夜,您辛苦了!由于当前在线用户较少,发布求助请尽量完整的填写文献信息,科研通机器人24小时在线,伴您度过漫漫科研夜!祝你早点完成任务,早点休息,好梦!

Does an Internal Joint Stabilizer and Standardized Protocol Prevent Recurrent Instability in Complex Persistent Elbow Instability?

肘部 医学 半脱位 外科 不稳定性 物理医学与康复
作者
Ching-Hou Ma,Yu-Huan Hsueh,Chin-Hsien Wu,Cheng-Yo Yen,Yuan-Kun Tu
出处
期刊:Clinical Orthopaedics and Related Research [Ovid Technologies (Wolters Kluwer)]
标识
DOI:10.1097/corr.0000000000002159
摘要

The treatment of complex persistent elbow instability after trauma is challenging. Previous studies on treatments have reported varied surgical techniques, which makes it difficult to establish a therapeutic algorithm. Furthermore, the surgical procedures may not sufficiently restore elbow stability, even with an additional device, and a noted high rate of arthritis progression.While a recently developed internal joint stabilizer effectively treats elbow instability, its clinical application for complex persistent elbow instability is limited and the standardized protocol is not well described. Additionally, we want to know whether the arthritis progression will cause a negative impact on the functional outcomes of complex persistent elbow instability.(1) Does treatment of complex persistent elbow instability with a hinged internal joint stabilizer and a standardized protocol prevent recurrent instability and other complications? (2) What are the pre- to postoperative improvements in pain, disability, elbow performance, and ROM? (3) Is the development of post-traumatic arthritis associated with worse pain, disability, elbow performance, and ROM?Between September 2014 and October 2019, we treated 22 patients for persistent dislocation or subluxation after initial treatment of traumatic elbow fracture-dislocations. Of those, we considered patients who were at least 20 years of age, with an interval of 6 weeks or more between the injury (initial treatment) and the index reconstructive procedure, which had been performed at our institute, as potentially eligible. During that time, we used an internal joint stabilizer with a standardized protocol for posttraumatic complex persistent elbow instability. We performed total elbow replacements in patients older than 50 years who had advanced elbow arthritis. Based on that, 82% (18 of 22) of patients eligible; 14% (3 of 22) were excluded because total elbow replacements was undertaken, and another 5% (1 of 22) were lost before the minimum study follow-up of 1 year (median 24 months [range 12 to 63]), leaving 64% (14 of 22) for analysis in this retrospective study. We treated 14 patients (14 elbows) with posttraumatic complex persistent elbow instability with an internal joint stabilizer and a standardized protocol that comprised of debridement arthroplasty with ulnar neurolysis, restoration of bony and ligamentous (reattachment) structures, application of an internal joint stabilizer, and early rehabilitation. There were eight men and six women in this study, with a median (range) age of 44 years (21 to 68). The initial elbow fracture-dislocation injury pattern was a terrible triad injury in seven patients, a posterolateral rotatory injury in four patients, and a posterior Monteggia fracture in three patients. Preoperative and follow-up radiographs were reviewed for evidence of recurrent instability and arthritis. Complications such as wound infection, seroma, neurovascular injury, and hardware complications were ascertained through chart review. Preoperative and postoperative VAS score for pain, DASH, and Mayo Elbow Performance Scores (MEPS) were collected and compared. Furthermore, extension-flexion and supination-pronation arcs were collected by chart review. We divided the patients into two groups according to whether or not they developed posttraumatic arthritis. We then presented the differences between pain, disability, elbow performance, and ROM. The hinged internal joint stabilizer was removed using another open procedure under general anesthesia 6 to 8 weeks after surgery.There were no recurrent instability during and after device removal. Seven patients developed complications, including wound infection, seroma, neurovascular injury, hardware complications, and heterotopic ossification. Two patients had complications related to internal joint stabilizers and three had complications linked to radial head prostheses. Median (range) preoperative to postoperative changes included decreased pain (VAS 5 [2 to 9] to 0 [0 to 3], difference of medians -5; p < 0.001), decreased disability (DASH 41 [16 to 66] to 7 [0 to 46], difference of medians -34; p < 0.001), improved function (MEPS 60 [25 to 70] to 95 [65 to 100], difference of medians 35; p < 0.001), improved extension-flexion arc (40° [10° to 70°] to 113° [75° to 140°], difference of medians 73°; p < 0.001), and supination-pronation arc (78° [30° to 165°] to 148° [70° to 175°], difference of medians 70°; p < 0.001). Between patients with and without development of post-traumatic arthritis, there were no differences in postoperative pain (VAS 0 [0 to 3] to 0 [0 to 1], difference of medians 0; p = 0.17), disability (DASH 7 [0 to 46] to 7 [0 to 18], difference of medians 0; p = 0.40), function (MEPS 80 [65 to 100] to 95 [75 to 100], difference of medians 15; p = 0.79), extension-flexion arc (105° [75° to 140°] to 115° 80° to 125°, difference of medians 10°; p = 0.40), and supination-pronation arc (155° [125° to 175°] to 135° [70° to 160°], difference of medians -20°; p < 0.18).In this small, retrospective study, we found that an internal joint stabilizer with a standardized treatment protocol could maintain concentric reduction while allowing early functional motion, and that it could improve clinical outcomes for patients with complex persistent elbow instability. However, patients must be counseled that the complications related to the radial head prostheses may occur, and that the benefits of early motion must compensate for an additional removal procedure and the risk of seroma formation.Level IV, therapeutic study.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
大幅提高文件上传限制,最高150M (2024-4-1)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
边曦完成签到 ,获得积分10
刚刚
亲爱的安德烈完成签到,获得积分10
1秒前
1秒前
hank完成签到 ,获得积分10
2秒前
3秒前
林狗完成签到 ,获得积分10
5秒前
9秒前
cocolu应助shaco采纳,获得30
14秒前
young完成签到 ,获得积分10
17秒前
18秒前
白日幻想家完成签到 ,获得积分10
20秒前
yx_cheng应助mbf采纳,获得10
26秒前
充电宝应助优美凡双采纳,获得10
31秒前
focus完成签到 ,获得积分10
32秒前
兜有米完成签到,获得积分10
34秒前
小情绪完成签到 ,获得积分10
35秒前
小二郎应助科研通管家采纳,获得10
36秒前
田様应助科研通管家采纳,获得10
37秒前
杳鸢应助科研通管家采纳,获得200
37秒前
37秒前
科研通AI2S应助科研通管家采纳,获得10
37秒前
Brain完成签到 ,获得积分10
39秒前
FFFFF完成签到 ,获得积分10
42秒前
领导范儿应助wjadejing采纳,获得10
42秒前
烟花应助自然的茉莉采纳,获得10
42秒前
43秒前
45秒前
47秒前
传奇3应助韵寒采纳,获得10
50秒前
51秒前
mbf发布了新的文献求助10
53秒前
53秒前
研友_5Y9Z75完成签到 ,获得积分0
55秒前
56秒前
wjadejing发布了新的文献求助10
1分钟前
领导范儿应助容言采纳,获得10
1分钟前
WUWUWU应助容言采纳,获得10
1分钟前
CodeCraft应助容言采纳,获得10
1分钟前
小二郎应助容言采纳,获得10
1分钟前
wjadejing完成签到,获得积分10
1分钟前
高分求助中
Licensing Deals in Pharmaceuticals 2019-2024 3000
Cognitive Paradigms in Knowledge Organisation 2000
Effect of reactor temperature on FCC yield 2000
Very-high-order BVD Schemes Using β-variable THINC Method 1020
Near Infrared Spectra of Origin-defined and Real-world Textiles (NIR-SORT): A spectroscopic and materials characterization dataset for known provenance and post-consumer fabrics 610
Promoting women's entrepreneurship in developing countries: the case of the world's largest women-owned community-based enterprise 500
Shining Light on the Dark Side of Personality 400
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 基因 遗传学 催化作用 物理化学 免疫学 量子力学 细胞生物学
热门帖子
关注 科研通微信公众号,转发送积分 3307263
求助须知:如何正确求助?哪些是违规求助? 2940973
关于积分的说明 8499935
捐赠科研通 2615205
什么是DOI,文献DOI怎么找? 1428778
科研通“疑难数据库(出版商)”最低求助积分说明 663525
邀请新用户注册赠送积分活动 648382