米诺地尔
色谱法
化学
志愿者
高效液相色谱法
校准曲线
萃取(化学)
再现性
药代动力学
变异系数
检出限
药理学
医学
内科学
农学
生物
作者
George Carrum,Darrell R. Abernethy,Maya Sadhukhan,Caroline Wright
出处
期刊:Journal of Chromatography B: Biomedical Sciences and Applications
[Elsevier]
日期:1986-01-01
卷期号:381: 127-135
被引量:17
标识
DOI:10.1016/s0378-4347(00)83571-9
摘要
A method is described for determination of minoxidil in human plasma using high-performance liquid chromatography with electrochemical detection. The method is specific and sensitive (500 pg/ml), however, minoxidil and minoxidil sulfate cannot be differentiated due to rapid autohydrolysis of minoxidil sulfate to minoxidil. The extraction procedure employs a C18 preparatory column to remove endogenous plasma constituents which would interfere with the assays. The calibration curves are linear for concentrations from 500 pg to 10 ng/ml. Within-day and between-day reproducibility are satisfactory with coefficient of variation less than 5.7% for all concentrations. Sample recovery from extraction is consistent at 45 to 55% at low and high concentrations, respectively. A pharmacokinetic study in a hypertensive volunteer receiving two different oral doses of minoxidil (1.25 and 2.5 mg) on different occasions demonstrates the utility of the method.
科研通智能强力驱动