Background: Thoracolumbar vertebral fractures are common pathological fractures caused by osteoporosis in the elderly. These fractures are challenging to detect. This study aimed to evaluate the diagnostic value of Hounsfield units for osteoporotic thoracolumbar vertebral non-compression fractures in elderly patients with low-energy fractures. Methods: The retrospective case-control study included elderly patients diagnosed with osteoporotic thoracolumbar vertebral fractures and non-fractured patients who underwent computed tomography examinations for lumbar vertebra issues during July 2017 and June 2020. Results: This study included 216 patients with fractures (38 males and 178 females; average age: 77.28± 8.68 years) and 124 patients without fractures (21 males and 103 females; average age: 75.35± 9.57 years). The difference in Hounsfield units of the target (intermediate) vertebral body significantly differed between the two groups (54.74 ± 21.84 vs 5.86 ± 5.14; p< 0.001). The ratios of Hounsfield units were also significantly different between the two groups (1.38 ± 1.60 vs 0.13 ± 0.23; p< 0.001). The cut-off value for the difference in Hounsfield units to detect osteoporotic spine fractures was 25.35, with high sensitivity (98.5%), specificity (99.9%), and the area under the curve (AUC) (0.999, 95% CI: 0.999– 1). The cut-off value for the odds ratio of Hounsfield units was 0.260, with high sensitivity (99.1%), specificity (92.7%), and AUC (0.970, 95% CI: 0.949– 0.992). Conclusion: The difference between Hounsfield units and the odds ratio of Hounsfield units might help diagnose osteoporotic thoracolumbar vertebral non-compression fractures in elderly patients with low-energy fractures. Keywords: multi-slice spiral computed tomography, thoracolumbar vertebrae, fractures, osteoporosis, morphological changes
科研通智能强力驱动
Strongly Powered by AbleSci AI