Diagnostic Performance of Modified Contrast-Enhanced Ultrasound Liver Imaging Reporting and Data System in Patients Without Risk Factors for Hepatocellular Carcinoma: Comparison With World Federation for Ultrasound in Medicine and Biology Guideline

医学 超声造影 肝细胞癌 指南 超声波 放射科 恶性肿瘤 局灶性结节性增生 曲线下面积 接收机工作特性 内科学 病理
作者
Yafang Zhang,Qing Li,Lingling Li,Yong Hong,Banghong Qiang,Yiwen Yu,Ruohan Guo,Hanxia Deng,Xu Han,Xuebin Zou,Zhixing Guo,Jianhua Zhou
出处
期刊:Ultrasound in Medicine and Biology [Elsevier BV]
卷期号:50 (2): 243-250 被引量:2
标识
DOI:10.1016/j.ultrasmedbio.2023.10.008
摘要

Objective The aim of this study was to assess the ability of the modified contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) to distinguish malignancy in patients without known hepatocellular carcinoma (HCC) risk factors and compare diagnostic accuracy with that of the World Federation for Ultrasound in Medicine and Biology (WFUMB) guideline across radiologists with different levels of CEUS experience. Methods A total of 848 individuals with no hepatitis infection presenting with 870 lesions in non-cirrhotic livers were included and divided into the Testing and Validation groups. The modified CEUS LI-RADS was proposed, including downgrading of focal nodular hyperplasia with typical features. Diagnostic performance of the modified CEUS LI-RADS was assessed in the Testing group. In the Validation group, two radiologists with more than 9 y of CEUS experience (Experts) and two radiologists with less than 6 mo of CEUS experience (Novices) used both the modified CEUS LI-RADS and the WFUMB guideline to evaluate performance in diagnosis of the lesions. Results LR-5 + M (combination of modified LR-5 and modified LR-M) revealed optimal performance with a sensitivity, specificity and area under the curve (AUC) of 99.3%, 81.6% and 0.904, respectively. Novices using the modified CEUS LI-RADS outperformed those using the WFUMB guideline (AUC: 0.858 vs. 0.767, p = 0.005). Additionally, the sensitivity, specificity and AUC of Novices were comparable to those of Experts using the modified CEUS LI-RADS (94.1%, 77.6% and 0.858 vs. 96.1%, 77.6% and 0.868 for experts, respectively). Conclusion The modified CEUS LI-RADS is a valuable method for distinguishing hepatic malignancy in patients without HCC risk factors. This is particularly beneficial for radiologists with limited CEUS expertise. The aim of this study was to assess the ability of the modified contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) to distinguish malignancy in patients without known hepatocellular carcinoma (HCC) risk factors and compare diagnostic accuracy with that of the World Federation for Ultrasound in Medicine and Biology (WFUMB) guideline across radiologists with different levels of CEUS experience. A total of 848 individuals with no hepatitis infection presenting with 870 lesions in non-cirrhotic livers were included and divided into the Testing and Validation groups. The modified CEUS LI-RADS was proposed, including downgrading of focal nodular hyperplasia with typical features. Diagnostic performance of the modified CEUS LI-RADS was assessed in the Testing group. In the Validation group, two radiologists with more than 9 y of CEUS experience (Experts) and two radiologists with less than 6 mo of CEUS experience (Novices) used both the modified CEUS LI-RADS and the WFUMB guideline to evaluate performance in diagnosis of the lesions. LR-5 + M (combination of modified LR-5 and modified LR-M) revealed optimal performance with a sensitivity, specificity and area under the curve (AUC) of 99.3%, 81.6% and 0.904, respectively. Novices using the modified CEUS LI-RADS outperformed those using the WFUMB guideline (AUC: 0.858 vs. 0.767, p = 0.005). Additionally, the sensitivity, specificity and AUC of Novices were comparable to those of Experts using the modified CEUS LI-RADS (94.1%, 77.6% and 0.858 vs. 96.1%, 77.6% and 0.868 for experts, respectively). The modified CEUS LI-RADS is a valuable method for distinguishing hepatic malignancy in patients without HCC risk factors. This is particularly beneficial for radiologists with limited CEUS expertise.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
活力书包完成签到 ,获得积分10
2秒前
法桐落梦完成签到,获得积分10
6秒前
四十四次日落完成签到 ,获得积分10
9秒前
tmobiusx完成签到,获得积分10
10秒前
wmc1357完成签到,获得积分10
15秒前
LILYpig完成签到 ,获得积分10
17秒前
大气夜山完成签到 ,获得积分10
19秒前
19秒前
一枝完成签到 ,获得积分10
19秒前
Jason完成签到 ,获得积分10
20秒前
量子星尘发布了新的文献求助10
25秒前
xmqaq完成签到,获得积分10
25秒前
殷勤的紫槐完成签到,获得积分10
26秒前
琳琳完成签到 ,获得积分10
26秒前
小蘑菇应助科研通管家采纳,获得10
28秒前
舒心的青亦完成签到 ,获得积分10
30秒前
卫卫完成签到 ,获得积分10
30秒前
等待的幼晴完成签到,获得积分10
30秒前
瘦瘦的铅笔完成签到 ,获得积分10
31秒前
SSDlk发布了新的文献求助10
33秒前
默默完成签到 ,获得积分10
33秒前
氟锑酸完成签到 ,获得积分10
35秒前
忞航完成签到 ,获得积分10
38秒前
Silence完成签到 ,获得积分10
40秒前
贰鸟应助王富贵采纳,获得10
43秒前
Smoiy完成签到 ,获得积分10
46秒前
weng完成签到,获得积分10
47秒前
笑笑完成签到,获得积分10
48秒前
pagemao完成签到 ,获得积分10
48秒前
49秒前
mbl2006完成签到 ,获得积分10
54秒前
背书强完成签到 ,获得积分10
54秒前
feihua1完成签到 ,获得积分10
55秒前
小亮哈哈完成签到,获得积分0
56秒前
Wang发布了新的文献求助10
56秒前
keleboys完成签到 ,获得积分10
56秒前
nine2652完成签到 ,获得积分10
1分钟前
姚怜南完成签到,获得积分10
1分钟前
1分钟前
wanghao完成签到 ,获得积分10
1分钟前
高分求助中
【提示信息,请勿应助】关于scihub 10000
A new approach to the extrapolation of accelerated life test data 1000
Coking simulation aids on-stream time 450
北师大毕业论文 基于可调谐半导体激光吸收光谱技术泄漏气体检测系统的研究 390
Phylogenetic study of the order Polydesmida (Myriapoda: Diplopoda) 370
Robot-supported joining of reinforcement textiles with one-sided sewing heads 360
Novel Preparation of Chitin Nanocrystals by H2SO4 and H3PO4 Hydrolysis Followed by High-Pressure Water Jet Treatments 300
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 遗传学 基因 物理化学 催化作用 冶金 细胞生物学 免疫学
热门帖子
关注 科研通微信公众号,转发送积分 4015603
求助须知:如何正确求助?哪些是违规求助? 3555597
关于积分的说明 11318138
捐赠科研通 3288782
什么是DOI,文献DOI怎么找? 1812284
邀请新用户注册赠送积分活动 887882
科研通“疑难数据库(出版商)”最低求助积分说明 812015