High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose

碘造影剂 医学 核医学 血管造影 扫描仪 冠状动脉造影 探测器 对比度(视觉) 放射科 计算机断层摄影术 物理 光学 内科学 心肌梗塞
作者
Prabhakar Rajiah,Chelsea A. S. Dunning,Kishore Rajendran,Yasmeen K. Tandon,Zaki Ahmed,Nicholas B. Larson,Jeremy D. Collins,Jamison E. Thorne,Eric E. Williamson,Joel G. Fletcher,Cynthia H. McCollough,Shuai Leng
出处
期刊:Investigative Radiology [Lippincott Williams & Wilkins]
被引量:21
标识
DOI:10.1097/rli.0000000000000961
摘要

Objectives The aim of this study was to evaluate the high-helical pitch, multienergy (ME) scanning mode of a clinical dual-source photon-counting detector (PCD) computed tomography (CT) and the benefit of virtual monoenergetic images (VMIs) for low-contrast-dose coronary CT angiography (CTA). Materials and Methods High-pitch (3.2) ME coronary CTA was performed in PCD-CT in 27 patients using low contrast dose (30 mL of iohexol 350 mg/mL) and in 26 patients at routine contrast dose (60 mL). Low-energy-threshold 120 kV images (also known as T3D images) and 50 kiloelectron volts (50 keV) and 100 kiloelectron volts (100 keV) VMIs were reconstructed using a 1024 × 1024 matrix and 0.6-mm slices. The CT numbers, noise, and contrast-to-noise ratio (CNR) were measured in the ascending aorta (AA), left main coronary artery (LMCA), and distal left anterior descending (LAD) artery. Confidence in grading luminal stenosis with calcific plaque, noncalcific plaque, and stent was evaluated by 2 independent readers on a 0–100 scale (0 the lowest), and a CAD-RADS score was assigned. Image contrast enhancement, sharpness, noise, artifacts, and overall image quality were rated using a 5-point ordinal scale (1 the lowest). Results The radiation doses (CTDI) in low- and routine-contrast cohorts were 2.5 ± 0.6 mGy and 3.1 ± 1.7 mGy, respectively ( P = 0.12). At all measured locations, the mean CT number was >300 HU in 120 kV (LMCA 382.9 ± 76.2, distal LAD 341.0 ± 53.9, AA 399.5 ± 76.1) and 50 keV images (LMCA 667.5 ± 139.9, distal LAD 578.1 ± 121.5, AA 700.8 ± 142.5) in the low-contrast cohort, with a 96% increase in CT numbers for 50 keV over 120 kV. The CT numbers were significantly higher ( P < 0.0001) in 50 keV than 120 kV and 100 keV VMI. The CNR was also significantly ( P < 0.0001) higher in 50 keV than 120 kV and 100 keV images in all vessels. Confidence in the assessment of luminal stenosis in the presence of calcific plaque was significantly higher ( P = 0.001) with the addition of 100 keV VMI (median score, 100) than using 50 keV alone (median score, 70) and 120 kV (median score, 70) for reader 1, but no significant differences were seen for reader 2 who had same median scores of 100 for all image types. The confidence in the assessment of luminal stenosis within a stent improved with the use of 100 keV images for both readers (reader 1: median scores for 50 + 100 keV = 100, 50 keV = 82.5, 120 kV = 82.5; reader 2: 50 + 100 keV = 100, 50 keV = 90, 120 kV = 90). There were no significant differences in confidence scores for assessment of luminal stenosis from noncalcific plaques for both readers. The reader-averaged qualitative scores for vascular enhancement and overall image quality were significantly higher for 50 keV VMI than for 120 kV images in both low- and routine-contrast dose cohorts. The image sharpness was nonsignificantly higher at 50 keV VMI than 120 kV images, and the artifact score was comparable for 50 keV VMI and 120 kV images. The noise was higher in 50 keV VMI than in 120 kV images. Conclusions High-pitch ME PCD-CT mode produced diagnostic quality coronary CTA images at low radiation and iodinated contrast doses. The availability of ME VMIs significantly improved the CNR, overall image quality, and confidence in assessment of luminal stenosis in the presence of calcific plaques and stents, and resulted in change of CAD-RADS categories in 9 patients.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
慕青应助科研进化中采纳,获得10
2秒前
2秒前
张大英关注了科研通微信公众号
3秒前
含蓄问安发布了新的文献求助10
3秒前
3秒前
胡萝卜发布了新的文献求助10
5秒前
pipichang完成签到,获得积分10
5秒前
有点鸭梨呀完成签到 ,获得积分10
6秒前
6秒前
7秒前
nnl完成签到,获得积分20
7秒前
袁咏琳冲冲冲完成签到,获得积分10
7秒前
WilliamJarvis完成签到 ,获得积分10
9秒前
斯文败类应助皮崇知采纳,获得10
9秒前
pzh完成签到 ,获得积分10
12秒前
无情寒荷发布了新的文献求助10
13秒前
打打应助含蓄问安采纳,获得10
15秒前
16秒前
皮崇知发布了新的文献求助10
20秒前
无情寒荷完成签到,获得积分10
21秒前
wangch198201完成签到 ,获得积分10
22秒前
坚定的小蘑菇完成签到 ,获得积分10
24秒前
xutong de完成签到,获得积分10
33秒前
迅速谷云完成签到,获得积分10
35秒前
zzyuyu完成签到 ,获得积分10
36秒前
鸣蜩十三完成签到,获得积分10
39秒前
xiuxiu完成签到 ,获得积分10
43秒前
念白完成签到 ,获得积分10
43秒前
GingerF应助科研通管家采纳,获得50
46秒前
小马甲应助科研通管家采纳,获得10
46秒前
天天快乐应助科研通管家采纳,获得10
46秒前
搜集达人应助科研通管家采纳,获得10
46秒前
科研通AI2S应助科研通管家采纳,获得10
46秒前
GingerF应助科研通管家采纳,获得10
46秒前
mg完成签到 ,获得积分10
47秒前
紧张的惜寒完成签到,获得积分10
48秒前
48秒前
可爱的函函应助清澈水眸采纳,获得10
50秒前
MM11111完成签到 ,获得积分10
54秒前
NexusExplorer应助dyh采纳,获得10
58秒前
高分求助中
Ophthalmic Equipment Market by Devices(surgical: vitreorentinal,IOLs,OVDs,contact lens,RGP lens,backflush,diagnostic&monitoring:OCT,actorefractor,keratometer,tonometer,ophthalmoscpe,OVD), End User,Buying Criteria-Global Forecast to2029 2000
A new approach to the extrapolation of accelerated life test data 1000
Cognitive Neuroscience: The Biology of the Mind 1000
Technical Brochure TB 814: LPIT applications in HV gas insulated switchgear 1000
Immigrant Incorporation in East Asian Democracies 500
Nucleophilic substitution in azasydnone-modified dinitroanisoles 500
不知道标题是什么 500
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 遗传学 基因 物理化学 催化作用 冶金 细胞生物学 免疫学
热门帖子
关注 科研通微信公众号,转发送积分 3965509
求助须知:如何正确求助?哪些是违规求助? 3510811
关于积分的说明 11155154
捐赠科研通 3245323
什么是DOI,文献DOI怎么找? 1792783
邀请新用户注册赠送积分活动 874096
科研通“疑难数据库(出版商)”最低求助积分说明 804176