腐蚀
冶金
材料科学
化学工程
化学
环境化学
工程类
作者
Longzhe Jin,Lu Wang,Dongke Chen
标识
DOI:10.1016/s1005-8850(06)60076-5
摘要
Abstract Metallic corrosion is a serious problem in the application of a hygroscopic inorganic dust-depressor. The basic characteristics of a hygroscopic inorganic dust-depressor and its corrosivity, corrosion mechanism, as well as the principle of corrosion inhibition were analyzed. The static mass-loss test was carried out to investigate the corrosion behavior and the effect of the dust-depressor. The static corrosion rates of steel specimens were measured in six different corrosion inhibitor solutions of the dust-depressor, and the suitable corrosion inhibitors for the dust-depressor to reduce the corrosivity were found out.