医学
纤维接头
牙科
极限抗拉强度
外科
粘附
口腔外科
刺激
材料科学
复合材料
免疫学
作者
Abdullah Faris,Lian Khalid,Mohammad Hashim,Sara Yaghi,Taif Magde,Ward Bouresly,Zaid Hamdoon,Asmaa T Uthman,Hesham Marei,Natheer H Al-Rawi
标识
DOI:10.1016/j.identj.2022.02.005
摘要
The aim of this review was to evaluate the most used suture materials with regards to their inflammatory response, their bacterial adhesion, and their physical properties when used to close oral wounds. Four databases (PubMed, Scopus, Dentistry & Oral Sciences, and OVID) were searched to retrieve relevant studies from January 1, 2000, to January 31, 2020. Out of the 269 articles, only 13 studies were selected as they were relevant and met the systematic review's protocol. These studies showed that almost all suture materials studies (catgut, polyglycolic acid [PGA] sutures, nylon, expanded polytetrafluoroethylene, and silk sutures) caused bacterial adherence and tissue reaction. In nylon and chromic catgut, the number of bacteria accumulated was lowest. Silk and nylon were found to be more impacted than catgut and PGA in terms of physical characteristics such as tensile strength. PGA, on the other hand, was said to be the most susceptible to knot unwinding. Following an oral surgical operation, all sutures revealed varied degrees of irritation and microbial accumulation. Nonresorbable monofilament synthetic sutures, however, exhibited less tissue response and less microbial accumulation.