化学
价值(数学)
电池(电)
纳米技术
统计
热力学
数学
物理
功率(物理)
材料科学
作者
Yang Xu,Chongqi Zhou,Lixuan Shi,Xiaonan Zhang,Tian Guan,Cuixia Guo,Zhangyan Li,Xin‐Hui Xing,Yanhong Ji,Le Liu,Yonghong He
标识
DOI:10.1021/acs.analchem.1c02189
摘要
Flow battery electrodes are vital for performing redox reactions, and an in-depth understanding of reaction kinetics and spatial distribution differences in electrodes is very important for improving the efficiency of electrochemical reactions. In this study, a reflection-type phase-sensitive weak measurement imaging system was developed for the detection of flow batteries. The phase difference between two polarization components in total internal reflection caused by electrode redox processes was measured by weak value amplification. The resulting refractive index resolution of the imaging system was estimated to be 2.8-4.2 × 10-6 RIU. The real-time monitoring ability of the system was demonstrated by linear sweep voltammetry tests of vanadium redox batteries. Compared to traditional optical methods, the proposed weak measurement imaging sensor did not require coating, as it can be used in acid electrolytes of vanadium flow batteries. Meanwhile, the weak value amplification effect led to a higher resolution than the total internal reflection system shown in our previous work, thereby resulting in more accurate detection of electrochemical reactions. In sum, the proposed sensor looks very promising for the detection of electrochemical reactions in flow batteries, water splitting, electrochemical corrosion, and electrocatalysis.
科研通智能强力驱动
Strongly Powered by AbleSci AI