Comparative Study of the Efficacy of the Ovarian-Adnexa Reporting and Data System Ultrasound Combined With Contrast-Enhanced Ultrasound and the ADNEX MR Scoring System in the Diagnosis of Adnexal Masses

医学 超声波 置信区间 超声造影 放射科 磁共振成像 超声科 妇科 内科学
作者
T Wang,Jun Zheng,Fang Nie,Xiao Huang,Lele Huang,Luping Liu,Yangyang Zhu,Rongfang Zheng
出处
期刊:Ultrasound in Medicine and Biology [Elsevier BV]
卷期号:49 (9): 2072-2080 被引量:2
标识
DOI:10.1016/j.ultrasmedbio.2023.05.012
摘要

Objective The aims of this study were to develop the Ovarian-Adnexa Reporting and Data System (O-RADS) and O-RADS + contrast-enhanced ultrasound (O-RADS CEUS) scoring system to distinguish adnexal masses (AMs) and to compare the diagnostic efficacy of these systems with that of a magnetic resonance imaging scoring system (ADNEX MR). Methods We retrospectively evaluated 278 ovarian masses from 240 patients between May 2017 and July 2022. Pathology and adequate follow-up were used as reference standards for comparing the validity of O-RADS, O-RADS CEUS and ADNEX MR scoring to diagnose AMs. Area under the curve (AUC), sensitivity and specificity were calculated. The inter-class correlation coefficient (ICC) was calculated to evaluate inter-reader agreement (IRA) between the two sonographers and two radiologists who analyzed the findings with the three modalities. Results The AUCs of O-RADS, O-RADS CEUS and ADNEX MR scores were 0.928 (95% confidence interval [CI]: 0.895–0.956), 0.951(95% CI: 0.919–0.973) and 0.964 (95% CI: 0.935–0.983), respectively. Their sensitivities were 95.7%, 94.3 and 91.4%, and their specificities were 81.3%, 92.3% and 97.1%, respectively. The three modalities had accuracies of 84.9%, 92.8% and 95.7%, respectively. O-RADS had the highest sensitivity but significantly lower specificity (p < 0.001), whereas the ADNEX MR scoring had the highest specificity (p < 0.001) but lower sensitivity (p < 0.001). O-RADS CEUS had intermediate sensitivity and specificity (p < 0.001). Conclusion The addition of CEUS significantly improves the efficacy of O-RADS in diagnosing AMs. The diagnostic efficacy of the combination is comparable to that of the ADNEX MR scoring system. The aims of this study were to develop the Ovarian-Adnexa Reporting and Data System (O-RADS) and O-RADS + contrast-enhanced ultrasound (O-RADS CEUS) scoring system to distinguish adnexal masses (AMs) and to compare the diagnostic efficacy of these systems with that of a magnetic resonance imaging scoring system (ADNEX MR). We retrospectively evaluated 278 ovarian masses from 240 patients between May 2017 and July 2022. Pathology and adequate follow-up were used as reference standards for comparing the validity of O-RADS, O-RADS CEUS and ADNEX MR scoring to diagnose AMs. Area under the curve (AUC), sensitivity and specificity were calculated. The inter-class correlation coefficient (ICC) was calculated to evaluate inter-reader agreement (IRA) between the two sonographers and two radiologists who analyzed the findings with the three modalities. The AUCs of O-RADS, O-RADS CEUS and ADNEX MR scores were 0.928 (95% confidence interval [CI]: 0.895–0.956), 0.951(95% CI: 0.919–0.973) and 0.964 (95% CI: 0.935–0.983), respectively. Their sensitivities were 95.7%, 94.3 and 91.4%, and their specificities were 81.3%, 92.3% and 97.1%, respectively. The three modalities had accuracies of 84.9%, 92.8% and 95.7%, respectively. O-RADS had the highest sensitivity but significantly lower specificity (p < 0.001), whereas the ADNEX MR scoring had the highest specificity (p < 0.001) but lower sensitivity (p < 0.001). O-RADS CEUS had intermediate sensitivity and specificity (p < 0.001). The addition of CEUS significantly improves the efficacy of O-RADS in diagnosing AMs. The diagnostic efficacy of the combination is comparable to that of the ADNEX MR scoring system.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
咕咕发布了新的文献求助10
刚刚
1秒前
虫虫太可爱了吧完成签到,获得积分10
3秒前
4秒前
豆子完成签到,获得积分10
5秒前
5秒前
李天翔完成签到,获得积分10
6秒前
6秒前
7秒前
图图发布了新的文献求助10
7秒前
7秒前
小蘑菇应助咕咕采纳,获得10
7秒前
涛老三完成签到 ,获得积分10
8秒前
悦耳的大炮完成签到,获得积分10
9秒前
可爱的函函应助rio采纳,获得10
9秒前
9秒前
9秒前
9秒前
超级安荷发布了新的文献求助20
9秒前
云ssss完成签到,获得积分10
9秒前
科研通AI6.1应助sjfczyh采纳,获得10
10秒前
天天快乐应助冷静迎海采纳,获得10
10秒前
风格化橙发布了新的文献求助10
11秒前
wxy发布了新的文献求助10
11秒前
超级玛丽发布了新的文献求助10
12秒前
12秒前
14秒前
默默尔安完成签到 ,获得积分10
15秒前
15秒前
16秒前
51发布了新的文献求助10
17秒前
17秒前
19秒前
Mo完成签到 ,获得积分10
19秒前
尊敬的雅青完成签到,获得积分10
19秒前
曾纪诚发布了新的文献求助10
20秒前
hou完成签到,获得积分10
21秒前
苏荷完成签到 ,获得积分10
21秒前
情怀应助浅丿颜采纳,获得10
23秒前
rio发布了新的文献求助10
24秒前
高分求助中
The Graphene Handbook (2019 Edition) 800
IEST-RP-CC018: Cleanroom Cleaning and Sanitization: Operating and Monitoring Procedures 600
Fundamentals of Pharmaceutical and Biologics Regulations: A Global Perspective, Second Edition 600
久松真一著作集〈第5巻〉禅と芸術 500
Fundamentals of Modern Mathematics: A Practical Review (Dover Books on Mathematics) 500
Cold War Transcended: Australia's China Policy, 1949-1990 470
Comprehensive Organic Synthesis 400
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 物理 内科学 复合材料 催化作用 物理化学 光电子学 电极 细胞生物学 基因 无机化学
热门帖子
关注 科研通微信公众号,转发送积分 6596932
求助须知:如何正确求助?哪些是违规求助? 8366841
关于积分的说明 17909700
捐赠科研通 5749694
什么是DOI,文献DOI怎么找? 2953219
邀请新用户注册赠送积分活动 1928537
关于科研通互助平台的介绍 1822447