Yiuwai Ng,Min‐Tsun Liao,Ting‐Li Chen,Chih‐Kuo Lee,Cheng‐Ying Chou,Weichung Wang
标识
DOI:10.1016/j.artmed.2023.102644
摘要
The proliferation of wearable devices has allowed the collection of electrocardiogram (ECG) recordings daily to monitor heart rhythm and rate. For example, 24-hour Holter monitors, cardiac patches, and smartwatches are widely used for ECG gathering and application. An automatic atrial fibrillation (AF) detector is required for timely ECG interpretation. Deep learning models can accurately identify AFs if large amounts of annotated data are available for model training. However, it is impractical to request sufficient labels for ECG recordings for an individual patient to train a personalized model. We propose a Siamese-network-based approach for transfer learning to address this issue. A pre-trained Siamese convolutional neural network is created by comparing two labeled ECG segments from the same patient. We sampled 30-second ECG segments with a 50% overlapping window from the ECG recordings of patients in the MIT-BIH Atrial Fibrillation Database. Subsequently, we independently detected the occurrence of AF in each patient in the Long-Term AF Database. By fine-tuning the model with the 1, 3, 5, 7, 9, or 11 ECG segments ranging from 30 to 180 s, our method achieved macro-F1 scores of 96.84%, 96.91%, 96.97%, 97.02%, 97.05%, and 97.07%, respectively.