Atrial high-rate episodes (AHREs) are prevalent in approximately 1/3 of patients with cardiac implanted electronic devices and are associated with an increased risk of several adverse outcomes. This study aimed to explore the factors associated with AHRE progression and the risk of all-cause mortality. At least 1 day with AHRE burden ≥15 minutes was identified in 124 of 343 recipients (36.2%) of an implantable cardioverter defibrillator or cardiac resynchronization therapy device. We included patients whose AHRE burden at the time of first detection was ≥15 minutes but <24 hours (n = 107). Various cut-off values (15 minutes, 6 hours, and 24 hours) of daily AHRE burden were analyzed. During an average follow-up of 4.2 years, 60 patients (56.1%) experienced ≥1 progression to greater AHRE burden. Patients with hypertension or greater AHRE burden at first detection were associated with faster progression. In addition, 27 deaths (45%) occurred among 60 patients with AHRE progression, compared with 25.5% (12 of 47) for those without progression. After multivariable adjustment, AHRE progression was independently associated with all-cause mortality (hazard ratio 2.56, 95% confidence interval 1.23 to 5.35, p = 0.012). Notably, AHRE progression within 1 month after their first detection was associated with an increased risk for all-cause mortality (hazard ratio 4.01, 95% confidence interval 1.76 to 9.16, p = 0.001) compared with patients without progression. However, a similar risk was not observed among patients with AHRE progression occurring after 1 month after their first detection. In conclusion, >1/2 of the patients with AHRE progressed to a greater burden over time. Continuous monitoring of the AHRE burden may help identify patients at great risk for death.