医学
二尖瓣
二尖瓣
狭窄
心脏病学
主动脉瓣狭窄
内科学
阀门更换
主动脉瓣置换术
冲程(发动机)
临床终点
主动脉瓣
外科
前瞻性队列研究
随机对照试验
工程类
机械工程
作者
John K. Forrest,Basel Ramlawi,G. Michael Deeb,Firas Zahr,Howard K. Song,Neal S. Kleiman,Stanley Chetcuti,Héctor I. Michelena,Abeel A. Mangi,Jeffrey Skiles,Jian Huang,Jeffrey J. Popma,Michael J. Reardon
出处
期刊:JAMA Cardiology
[American Medical Association]
日期:2020-10-07
被引量:65
标识
DOI:10.1001/jamacardio.2020.4738
摘要
The outcomes of transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic valve stenosis have not been studied in a large scale, multicentered, prospective fashion.To evaluate the procedural safety, efficacy, and 30-day outcomes of TAVR in patients with bicuspid aortic stenosis at low surgical risk.The Low Risk Bicuspid Study is a prospective, single-arm trial study with inclusion/exclusion criteria developed from the Evolut Low Risk Randomized Trial. Follow-up is planned for 10 years. Patients underwent TAVR at 25 centers in the United States who were also participating in the Evolut Low Risk Randomized Trial from December 2018 to October 2019. Eligible patients had severe bicuspid aortic valve stenosis and met American Heart Association/American College of Cardiology guideline indications for aortic valve replacement.Patients underwent attempted implant of an Evolut or Evolut PRO transcatheter aortic valve, with valve size based on annular measurements.The prespecified primary end point was the incidence of all-cause mortality or disabling stroke at 30 days. The prespecified primary efficacy end point was device success defined as the absence of procedural mortality, the correct position of 1 bioprosthetic heart valve in the proper anatomical location, and the absence of more than mild aortic regurgitation postprocedure.A total of 150 patients underwent an attempted implant. Baseline characteristics include mean age of 70.3 (5.5) years, 48.0% female (n = 72), and a mean Society of Thoracic Surgeons score of 1.4 (0.6%). Most patients (136; 90.7%) had Sievers type I valve morphology. The incidence of all-cause mortality or disabling stroke was 1.3% (95% CI, 0.3%-5.3%) at 30 days. The device success rate was 95.3% (95% CI, 90.5%-98.1%). At 30 days, the mean (SD) AV gradient was 7.6 (3.7) mm Hg and effective orifice area was 2.3 (0.7) cm2. A new permanent pacemaker was implanted in 22 patients (15.1%). No patients had greater than mild paravalvular leak.Transcatheter aortic valve replacement in low-surgical risk patients with bicuspid aortic valve stenosis achieved favorable 30-day results, with low rates of death and stroke and high device success rate.ClinicalTrials.gov Identifier: NCT03635424.
科研通智能强力驱动
Strongly Powered by AbleSci AI