Accurate Detection of Doppler Cardiograms With a Parameterized Respiratory Filter Technique Using a K-Band Radar Sensor
参数化复杂度
多普勒雷达
计算机科学
雷达
人工智能
多普勒效应
算法
电信
物理
天文
作者
Shuqin Dong,Yuchen Li,Jingyun Lu,Zhi Zhang,Changzhan Gu,Junfa Mao
出处
期刊:IEEE Transactions on Microwave Theory and Techniques日期:2022-06-24卷期号:71 (1): 71-82被引量:27
标识
DOI:10.1109/tmtt.2022.3184019
摘要
Cardiogram is one of the most important factors for health assessment. As a new expression of cardiograms, the Doppler cardiograms (DCGs) detected remotely via Doppler radar sensor (DRS) provide rich details of the heart motion. However, the existing techniques for measurement of DCG requires that the subject holds his/her breath to avoid the disturbance caused by respiration. To realize the accurate detection of DCGs in the presence of respiration, a high-linearity $K$ -band dc-coupled continuous-wave (CW) DRS with digital dc-tuning function was custom-designed and a novel parameterized respiratory filter (PRF) algorithm was proposed to precisely remove the respiratory signal. Both simulation and experimental results show that the proposed PRF algorithm has better DCG extraction performance than the conventional methods. Furthermore, the experimental results in normal and clinical environments show that the grained differential DCG (D-DCG) has promising potential in professional heart rate variability (HRV) analysis and heart diseases diagnosis, which means the proposed DCGs detection has the potential to be a convenient, comfortable, and reliable way for daily and clinical heart health assessment.