Michel Montaudon,Patrick Berger,Hervé Blachère,Laurent De Boucaud,Valérie Latrabe,François Laurent
标识
DOI:10.1007/s003300000810
摘要
The aim of this study was to determine if ECG triggering and a shorter acquisition time of 0.5-s rotation decrease cardiac motion artifacts of thin-section CT of the lung. In 25 patients referred for thin-section thoracic CT, 1-mm thin-section slices were performed with a scanning time of 0.5 s with ECG gating, 0.5 s and 1 s during the diastolic phase of the heart at five identical anatomical levels from the aortic arch to lung basis. At each anatomical level and for each lung, cardiac motion artifacts were graded independently on a four-point scale by three readers. Patients were divided into two groups according to their heart rate. A four-way analysis of variance was used to assess differences between the three modalities. Mean cardiac motion artifacts scores were rated 1.23±0.02, 1.47±0.02, and 1.79±0.02, at 0.5 s with ECG gating, 0.5 s without ECG gating, and 1 s, respectively (F=139, p<0.0001). At the four anatomical levels below the aortic arch, the left lung scores were greater than the right lung score for the three modalities. For the modality 0.5 s with ECG gating no difference of scores was found between patients grouped according to their cardiac frequency. The 0.5-s gantry rotation with or without ECG gating scans reduces cardiac motion artifacts on pulmonary thin-section CT images and is mainly beneficial for the lower part of the left lung.