拉曼光谱
残余物
工艺工程
材料科学
电压
分析化学(期刊)
计算机科学
电气工程
化学
工程类
光学
色谱法
物理
算法
作者
Mark S. Kemper,Christian Philippczyk,Robert J. Rayzak,V. Waschk
出处
期刊:IEEE Transactions on Power Delivery
[Institute of Electrical and Electronics Engineers]
日期:2010-12-29
卷期号:26 (1): 3-10
被引量:10
标识
DOI:10.1109/tpwrd.2010.2089704
摘要
The residual products of the cross-linking process for high-voltage (HV) and medium-voltage (MV) cable materials are manifold but the two most important byproducts are cumyl alcohol (CA) and acetophenone (AC). Due in part to the presence of these byproducts, cables must be degassed for several days at elevated temperature before the product can be shipped, possibly limiting production throughput. There are few analytical means available to conveniently monitor the quantities of these byproducts during degassing. In this paper, we describe the use of a recently developed technology and enhanced measurement technique that employs large-spot Raman spectroscopy for the quantification of CA and AC. The sampling involves the use of an incident laser spot which can range from 1 to 6 mm in diameter to facilitate the achievement of accurate quantitative results. This approach would allow monitoring of degassing so that an accurate, results-oriented specification could be set for the shipment of HV and MV cable products following production. As such, this methodology has the potential to facilitate better product consistency among manufacturers.
科研通智能强力驱动
Strongly Powered by AbleSci AI