CT Number Accuracy and Association With Object Size: A Phantom Study Comparing Energy-Integrating Detector CT and Deep Silicon Photon-Counting Detector CT

成像体模 探测器 核医学 医学 能量(信号处理) 光子计数 光子 医学物理学 光学 物理 光电子学 量子力学
作者
A. M. Salyapongse,Sean D. Rose,Perry J. Pickhardt,Meghan G. Lubner,Giuseppe V. Toia,Robert Bujila,Zhye Yin,Scott Slavic,Timothy P. Szczykutowicz
出处
期刊:American Journal of Roentgenology [American Roentgen Ray Society]
卷期号:221 (4): 539-547 被引量:9
标识
DOI:10.2214/ajr.23.29463
摘要

BACKGROUND. Variable beam hardening based on patient size causes variation in CT numbers for energy-integrating detector (EID) CT. Photon-counting detector (PCD) CT more accurately determines effective beam energy, potentially improving CT number reliability. OBJECTIVE. The purpose of the present study was to compare EID CT and deep silicon PCD CT in terms of both the effect of changes in object size on CT number and the overall accuracy of CT numbers. METHODS. A phantom with polyethylene rings of varying sizes (mimicking patient sizes) as well as inserts of different materials was scanned on an EID CT scanner in single-energy (SE) mode (120-kV images) and in rapid-kilovoltage-switching dual-energy (DE) mode (70-keV images) and on a prototype deep silicon PCD CT scanner (70-keV images). ROIs were placed to measure the CT numbers of the materials. Slopes of CT number as a function of object size were computed. Materials' ideal CT number at 70 keV was computed using the National Institute of Standards and Technology XCOM Photon Cross Sections Database. The root mean square error (RMSE) between measured and ideal numbers was calculated across object sizes. RESULTS. Slope (expressed as Hounsfield units per centimeter) was significantly closer to zero (i.e., less variation in CT number as a function of size) for PCD CT than for SE EID CT for air (1.2 vs 2.4 HU/cm), water (-0.3 vs -1.0 HU/cm), iodine (-1.1 vs -4.5 HU/cm), and bone (-2.5 vs -10.1 HU/cm) and for PCD CT than for DE EID CT for air (1.2 vs 2.8 HU/cm), water (-0.3 vs -1.0 HU/cm), polystyrene (-0.2 vs -0.9 HU/cm), iodine (-1.1 vs -1.9 HU/cm), and bone (-2.5 vs -6.2 HU/cm) (p < .05). For all tested materials, PCD CT had the smallest RMSE, indicating CT numbers closest to ideal numbers; specifically, RMSE (expressed as Hounsfield units) for SE EID CT, DE EID CT, and PCD CT was 32, 44, and 17 HU for air; 7, 8, and 3 HU for water; 9, 10, and 4 HU for polystyrene; 31, 37, and 13 HU for iodine; and 69, 81, and 20 HU for bone, respectively. CONCLUSION. For numerous materials, deep silicon PCD CT, in comparison with SE EID CT and DE EID CT, showed lower CT number variability as a function of size and CT numbers closer to ideal numbers. CLINICAL IMPACT. Greater reliability of CT numbers for PCD CT is important given the dependence of diagnostic pathways on CT numbers.

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
是蔡同学完成签到,获得积分10
刚刚
完美世界应助大头采纳,获得30
1秒前
muscus完成签到,获得积分10
1秒前
1秒前
浅汐发布了新的文献求助10
1秒前
1秒前
崔雨旋完成签到,获得积分10
2秒前
鲤鱼一手完成签到,获得积分10
3秒前
MYSHOW发布了新的文献求助10
4秒前
4秒前
4秒前
科研通AI6.3应助mofeik采纳,获得10
5秒前
善学以致用应助向上采纳,获得10
5秒前
小虾米完成签到,获得积分10
6秒前
希望天下0贩的0应助陈瑞采纳,获得10
6秒前
落寞的千愁完成签到 ,获得积分10
6秒前
郝冠希发布了新的文献求助10
6秒前
次我完成签到,获得积分10
7秒前
于玕驳回了今后应助
7秒前
7秒前
萝卜花1968发布了新的文献求助10
9秒前
bkagyin应助涵泽采纳,获得10
9秒前
sweet0225完成签到,获得积分10
9秒前
LI发布了新的文献求助10
10秒前
田様应助hoh采纳,获得10
11秒前
安详的海秋完成签到,获得积分10
11秒前
手可摘星辰完成签到,获得积分10
12秒前
善学以致用应助yihanghh采纳,获得10
12秒前
fortune发布了新的文献求助10
12秒前
13秒前
郝冠希完成签到,获得积分10
13秒前
wanci应助阿巴阿巴采纳,获得10
13秒前
ding应助Polarbear29采纳,获得10
13秒前
14秒前
山雀完成签到 ,获得积分10
16秒前
YRHM完成签到 ,获得积分10
16秒前
十一完成签到,获得积分10
17秒前
善学以致用应助qq采纳,获得10
18秒前
spinon发布了新的文献求助10
18秒前
Ada纾完成签到 ,获得积分10
19秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
The Wiley Blackwell Companion to Diachronic and Historical Linguistics 3000
The impact of workplace variables on juvenile probation officers’ job satisfaction 1000
When the badge of honor holds no meaning anymore 1000
HANDBOOK OF CHEMISTRY AND PHYSICS 106th edition 1000
ASPEN Adult Nutrition Support Core Curriculum, Fourth Edition 1000
AnnualResearch andConsultation Report of Panorama survey and Investment strategy onChinaIndustry 1000
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 物理 内科学 复合材料 催化作用 物理化学 光电子学 电极 细胞生物学 基因 无机化学
热门帖子
关注 科研通微信公众号,转发送积分 6282295
求助须知:如何正确求助?哪些是违规求助? 8101163
关于积分的说明 16938669
捐赠科研通 5349299
什么是DOI,文献DOI怎么找? 2843405
邀请新用户注册赠送积分活动 1820606
关于科研通互助平台的介绍 1677542