电解
污染
质子交换膜燃料电池
化学
杂质
离子交换
膜
离子
无机化学
电极
生态学
生物化学
电解质
生物
物理化学
有机化学
作者
Na Li,Samuel Simon Araya,Xiaoti Cui,Søren Knudsen Kær
标识
DOI:10.1016/j.jpowsour.2020.228617
摘要
This paper investigates the effects of impurities contamination on the performance of a proton exchange membrane (PEM) water electrolyzer. The impacts of Fe3+, Cu2+ and Al3+ ions on the performance of single PEM water electrolysis cells are investigated by introducing Fe2(SO4)3, CuSO4, Al2(SO4)3 solution into deionized water to prepare 5 parts per million (ppm, molar ratio) contaminated feed solution. The prepared solution was then fed to the PEM water electrolysis system to carry out the contamination test. The results show that the single cell performance experienced a dramatic decrease initially but then recovered to some degree during the Fe3+ ions contamination. For Cu2+ ions contamination, the cell ohmic resistance decreased while the charge and mass transfer resistance showed an increasing trend throughout the test period. Moreover, the Al3+ ions can cause a sudden cell failure when introduced into the cell.