控制理论(社会学)
振动
定子
计算机科学
同步电动机
电压
还原(数学)
阻尼转矩
功率(物理)
振幅
作者
Heonyoung Kim,Sang Bin Lee,Sung Bong Park,Shahin Hedayati Kia,Gerard-Andre Capolino
出处
期刊:IEEE Transactions on Industry Applications
[Institute of Electrical and Electronics Engineers]
日期:2016-03-01
卷期号:52 (2): 1460-1468
被引量:39
标识
DOI:10.1109/tia.2015.2508423
摘要
Low-frequency torque oscillations in the load can induce frequency components in the vicinity of that of rotor faults (RFs) resulting in false alarms when applying motor current signature analysis (MCSA). False RF indications due to load oscillations (LO) are most common in applications that employ speed reduction couplings for high torque, low-speed operation. Recently, ideas for separating RF and LO have been proposed in the literature; however, the case where two components overlap at the same frequency has not been investigated. Several cases where RF- and LO-induced components are identical have been observed in the field by the authors with commercial MCSA equipment. It is shown in this paper that overlap between the two components can produce a false positive or false negative indication because they can add or cancel depending on the relative phase between the components. Alternative options for reliable RF testing among existing test methods are evaluated and verified in this paper for cases where the two components overlap and produce false indications.