医学
血管内超声
支架
放射科
心肌梗塞
药物洗脱支架
血运重建
血管造影
危险系数
依维莫司
经皮冠状动脉介入治疗
内科学
心脏病学
靶病变
再狭窄
置信区间
作者
Sung‐Jin Hong,Byeong‐Keuk Kim,Dong‐Ho Shin,Chung Mo Nam,Jung‐Sun Kim,Young‐Guk Ko,Donghoon Choi,Tae Soo Kang,Woong Chol Kang,Ae‐Young Her,Yong Hoon Kim,Seung‐Ho Hur,Bum–Kee Hong,Hyuck Moon Kwon,Yangsoo Jang,Myeong‐Ki Hong
出处
期刊:JAMA
[American Medical Association]
日期:2015-11-10
卷期号:314 (20): 2155-2155
被引量:477
标识
DOI:10.1001/jama.2015.15454
摘要
Use of intravascular ultrasound (IVUS) promotes better clinical outcomes for coronary intervention in complex coronary lesions. However, randomized data demonstrating the clinical usefulness of IVUS are limited for lesions treated with drug-eluting stents.To determine whether the long-term clinical outcomes with IVUS-guided drug-eluting stent implantation are superior to those with angiography-guided implantation in patients with long coronary lesions.The Impact of Intravascular Ultrasound Guidance on Outcomes of Xience Prime Stents in Long Lesions (IVUS-XPL) randomized, multicenter trial was conducted in 1400 patients with long coronary lesions (implanted stent ≥28 mm in length) between October 2010 and July 2014 at 20 centers in Korea.Patients were randomly assigned to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation.Primary outcome measure was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 1 year, analyzed by intention-to-treat.One-year follow-up was complete in 1323 patients (94.5%). Major adverse cardiac events at 1 year occurred in 19 patients (2.9%) undergoing IVUS-guided and in 39 patients (5.8%) undergoing angiography-guided stent implantation (absolute difference, -2.97% [95% CI, -5.14% to -0.79%]) (hazard ratio [HR], 0.48 [95% CI, 0.28 to 0.83], P = .007). The difference was driven by a lower risk of ischemia-driven target lesion revascularization in patients undergoing IVUS-guided (17 [2.5%]) compared with angiography-guided (33 [5.0%]) stent implantation (HR, 0.51 [95% CI, 0.28 to 0.91], P = .02). Cardiac death and target lesion-related myocardial infarction were not significantly different between the 2 groups. For cardiac death, there were 3 patients (0.4%) in the IVUS-guided group and 5 patients (0.7%) in the angiography-guided group (HR, 0.60 [95% CI, 0.14 to 2.52], P = .48). Target lesion-related myocardial infarction occurred in 1 patient (0.1%) in the angiography-guided stent implantation group (P = .32).Among patients requiring long coronary stent implantation, the use of IVUS-guided everolimus-eluting stent implantation, compared with angiography-guided stent implantation, resulted in a significantly lower rate of the composite of major adverse cardiac events at 1 year. These differences were primarily due to lower risk of target lesion revascularization.clinicaltrials.gov Identifier: NCT01308281.
科研通智能强力驱动
Strongly Powered by AbleSci AI