氧化铝陶瓷
陶瓷
GSM演进的增强数据速率
材料科学
全髋关节置换术
全髋关节置换术
复合材料
医学
外科
计算机科学
电信
作者
Christina I. Esposito,William L. Walter,A. Roques,M. Tuke,B. Zicat,William R. Walsh,William L. Walter
出处
期刊:The journal of bone and joint surgery
[British Editorial Society of Bone and Joint Surgery]
日期:2012-06-25
卷期号:94-B (7): 901-907
被引量:66
标识
DOI:10.1302/0301-620x.94b7.29115
摘要
We analysed 54 alumina ceramic-on-ceramic bearings from total hip replacements retrieved at one centre after a mean duration of 3.5 years (0.2 to 10.6) in situ. These implants were obtained from 54 patients (16 men and 38 women) with a mean age of 67 years (33 to 88) who underwent revision for a variety of reasons. Posterior edge loading was found in the majority of these retrievals (32 out of 54). Anterosuperior edge loading occurred less often but produced a higher rate of wear. Stripe wear on the femoral heads had a median volumetric wear rate of 0.2 mm 3 /year (0 to 7.2). The wear volume on the femoral heads corresponded to the width of edge wear on the matching liner. Anteversion of the acetabular component was found to be a more important determinant than inclination for wear in ceramic bearings. Posterior edge loading may be considered to be a normal occurrence in ceramic-on-ceramic bearings, with minimal clinical consequences. Edge loading should be defined as either anterosuperior or posterior, as each edge loading mechanism may result in different clinical implications.
科研通智能强力驱动
Strongly Powered by AbleSci AI