探测量子效率
光传递函数
探测器
光学
X射线探测器
量子效率
物理
灵敏度(控制系统)
图像传感器
图像分辨率
像素
光电子学
材料科学
图像质量
电子工程
图像(数学)
计算机科学
工程类
人工智能
作者
Md. Tanvir Kabir,S. O. Kasap,Wei Zhao,J. A. Rowlands
出处
期刊:IEE proceedings
[Institution of Electrical Engineers]
日期:2003-01-01
卷期号:150 (4): 258-258
被引量:16
标识
DOI:10.1049/ip-cds:20030663
摘要
Imaging characteristics of photoconductive flat panel X-ray image detectors, such as X-ray sensitivity, detective quantum efficiency (DQE), and resolution in terms of the modulation transfer function (MTF) are examined with applications to amorphous selenium (a-Se), polycrystalline HgI2 and CdZnTe detectors. A theoretical model has been developed for the calculation of X-ray sensitivity of a pixellated detector by using the Shockley–Ramo theorem, the weighting potential of the individual pixel and the final trapped charge distribution across the photoconductor. The X-ray sensitivity of pixellated X-ray detectors mostly depends on the mobility and lifetime product of charges that move towards the pixel electrodes, and the extent of dependence increases with decreasing pixel per unit detector thickness. A cascaded linear system model that includes incomplete charge collection and interaction depth dependent conversion gain and charge collection stages is considered for the calculation of the zero spatial frequency detective quantum efficiency DQE(0) of a direct conversion X-ray image detector. The DQE(0) performance of a-Se, HgI2 and CdZnTe detectors is examined for fluoroscopic applications. It is shown that, in addition to high quantum efficiency, both high conversion gain and high charge collection efficiency are required to improve the DQE performance of an X-ray image detector. The factors affecting the MTF of a-Se flat-panel detectors for digital mammography are investigated. Both theoretical and experimental methods are examined. A theoretical model has been developed based on cascaded linear system analysis with parallel processes to take into account the effect of K-fluorescence. This model has been used to understand the performance of a small-area prototype detector with 85 μm pixel size. The presampling MTF of the prototype has been measured and compared to a theoretical calculation based on the model. The calculation shows that K-fluorescence accounts for a 15% reduction in the MTF at the Nyquist frequency of the prototype detector. The measurement of presampling MTF of the prototype detector reveals an additional source of blurring, which is probably due to charge carrier trapping in the blocking layer at the interface between a-Se and the active matrix. This introduces a drop in presampling MTF at high spatial frequencies.
科研通智能强力驱动
Strongly Powered by AbleSci AI