Ziyu Wang,Yulin Li,Jianbin Pan,Meiyun Xu,Jing‐Juan Xu,Daoben Hua
标识
DOI:10.1016/j.jhazmat.2023.131449
摘要
The World Health Organization has reported radioactive Rn gas as the second leading cause of lung cancer and gives an extreme limit to indoor Radon (Rn) concentration as 100 Bq/m3. To realize rapid and accurate Rn monitoring, we report an efficient visualized electrochemiluminescence (ECL) device for Rn detection with the lowest limit of detection (0.9 Bq/m3/3.6 Bq h m−3) compared to known Rn detection methods and the shortest measurement time (less than 5 h) among non-pump methods. In detail, an efficient Rn probe is prepared by Au nanoparticles, Pb2+ aptamer, as well as NH2-ssDNA co-reactant and then modified on ITO electrodes to obtain Rn detection devices. With tris(2,2′-bipyridyl)ruthenium(II)chloride (Ru(bpy)3Cl2) as an ECL emitter, the devices can exhibit ultra-high sensitivity and selectivity to trace Rn in environment via the ECL quenching caused by 210Pb, the relatively stable decay product of Rn. Furthermore, ECL imaging technology can be applied to realize the visualized Rn detection. An efficient up-response ECL detector was also invented to support this detection device to achieve accurate Rn detection in environment. This work reports noble gas ECL detection for the first time and provides an efficient strategy for rapid and accurate monitoring of trace Rn in environment.