Assessment of Transarterial Chemoembolization Using Super-resolution Ultrasound Imaging and a Rat Model of Hepatocellular Carcinoma

肝细胞癌 医学 碘化油 超声波 放射科 磁共振成像 超声造影 核医学 内科学
作者
Katherine Brown,Junjie Li,Ryan Margolis,Brian Trinh,John R. Eisenbrey,Kenneth Hoyt
出处
期刊:Ultrasound in Medicine and Biology [Elsevier BV]
卷期号:49 (5): 1318-1326 被引量:20
标识
DOI:10.1016/j.ultrasmedbio.2023.01.021
摘要

Objective Hepatocellular carcinoma (HCC) is a highly prevalent form of liver cancer diagnosed annually in 600,000 people worldwide. A common treatment is transarterial chemoembolization (TACE), which interrupts the blood supply of oxygen and nutrients to the tumor mass. The need for repeat TACE treatments may be assessed in the weeks after therapy with contrast-enhanced ultrasound (CEUS) imaging. Although the spatial resolution of traditional CEUS has been restricted by the diffraction limit of ultrasound (US), this physical barrier has been overcome by a recent innovation known as super-resolution US (SRUS) imaging. In short, SRUS enhances the visible details of smaller microvascular structures on the 10 to 100 µm scale, which unlocks a host of new clinical opportunities for US. Methods In this study, a rat model of orthotopic HCC is introduced and TACE treatment response (to a doxorubicin-lipiodol emulsion) is assessed using longitudinal SRUS and magnetic resonance imaging (MRI) performed at 0, 7 and 14 d. Animals were euthanized at 14 d for histological analysis of excised tumor tissue and determination of TACE response, that is, control, partial response or complete response. CEUS imaging was performed using a pre-clinical US system (Vevo 3100, FUJIFILM VisualSonics Inc.) equipped with an MX201 linear array transducer. After administration of a microbubble contrast agent (Definity, Lantheus Medical Imaging), a series of CEUS images were collected at each tissue cross-section as the transducer was mechanically stepped at 100 μm increments. SRUS images were formed at each spatial position, and a microvascular density metric was calculated. Microscale computed tomography (microCT, OI/CT, MILabs) was used to confirm TACE procedure success, and tumor size was monitored using a small animal MRI system (BioSpec 3T, Bruker Corp.). Results Although there were no differences at baseline (p > 0.15), both microvascular density levels and tumor size measures from the complete responder cases at 14 d were considerably lower and smaller, respectively, than those in the partial responder or control group animals. Histological analysis revealed tumor-to-necrosis levels of 8.4%, 51.1% and 100%, for the control, partial responder and complete responder groups, respectively (p < 0.005). Conclusion SRUS imaging is a promising modality for assessing early changes in microvascular networks in response to tissue perfusion-altering interventions such as TACE treatment of HCC. Hepatocellular carcinoma (HCC) is a highly prevalent form of liver cancer diagnosed annually in 600,000 people worldwide. A common treatment is transarterial chemoembolization (TACE), which interrupts the blood supply of oxygen and nutrients to the tumor mass. The need for repeat TACE treatments may be assessed in the weeks after therapy with contrast-enhanced ultrasound (CEUS) imaging. Although the spatial resolution of traditional CEUS has been restricted by the diffraction limit of ultrasound (US), this physical barrier has been overcome by a recent innovation known as super-resolution US (SRUS) imaging. In short, SRUS enhances the visible details of smaller microvascular structures on the 10 to 100 µm scale, which unlocks a host of new clinical opportunities for US. In this study, a rat model of orthotopic HCC is introduced and TACE treatment response (to a doxorubicin-lipiodol emulsion) is assessed using longitudinal SRUS and magnetic resonance imaging (MRI) performed at 0, 7 and 14 d. Animals were euthanized at 14 d for histological analysis of excised tumor tissue and determination of TACE response, that is, control, partial response or complete response. CEUS imaging was performed using a pre-clinical US system (Vevo 3100, FUJIFILM VisualSonics Inc.) equipped with an MX201 linear array transducer. After administration of a microbubble contrast agent (Definity, Lantheus Medical Imaging), a series of CEUS images were collected at each tissue cross-section as the transducer was mechanically stepped at 100 μm increments. SRUS images were formed at each spatial position, and a microvascular density metric was calculated. Microscale computed tomography (microCT, OI/CT, MILabs) was used to confirm TACE procedure success, and tumor size was monitored using a small animal MRI system (BioSpec 3T, Bruker Corp.). Although there were no differences at baseline (p > 0.15), both microvascular density levels and tumor size measures from the complete responder cases at 14 d were considerably lower and smaller, respectively, than those in the partial responder or control group animals. Histological analysis revealed tumor-to-necrosis levels of 8.4%, 51.1% and 100%, for the control, partial responder and complete responder groups, respectively (p < 0.005). SRUS imaging is a promising modality for assessing early changes in microvascular networks in response to tissue perfusion-altering interventions such as TACE treatment of HCC.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
香菜发布了新的文献求助10
刚刚
1秒前
科研小菜发布了新的文献求助10
6秒前
飞快的邴完成签到,获得积分10
8秒前
斯文败类应助_太空_采纳,获得10
8秒前
不开花花完成签到 ,获得积分10
8秒前
9秒前
ydz完成签到,获得积分10
10秒前
沉静从阳完成签到,获得积分10
10秒前
10秒前
风中琦完成签到 ,获得积分10
11秒前
jixia完成签到,获得积分10
11秒前
万象更新完成签到,获得积分10
11秒前
13秒前
13秒前
13秒前
14秒前
天天向上发布了新的文献求助10
14秒前
nanana发布了新的文献求助10
15秒前
55555完成签到,获得积分10
15秒前
juanjuan发布了新的文献求助10
15秒前
花痴的手套完成签到 ,获得积分10
17秒前
jixia发布了新的文献求助10
17秒前
细心盼晴发布了新的文献求助10
18秒前
戴士杰686完成签到,获得积分10
18秒前
wwwteng呀完成签到,获得积分10
19秒前
zhong完成签到 ,获得积分10
19秒前
程哲瀚完成签到,获得积分10
20秒前
科研通AI6.3应助zhouxiaoyu采纳,获得10
20秒前
123完成签到,获得积分10
21秒前
21秒前
22秒前
23秒前
24秒前
Marksman497发布了新的文献求助10
25秒前
25秒前
所爱皆在完成签到 ,获得积分10
25秒前
25秒前
Marksman497发布了新的文献求助10
26秒前
26秒前
高分求助中
Markov Chain Monte Carlo 10000
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Bend stiffness of submarine cables – an experimental and numerical investigation 5000
Advanced Weaponeering Fourth Edition, Volume 2 1000
Weaponeering: An Introduction Fourth Edition, Volume 1 1000
悉尼大学博士学位论文,题目:Modelling and testing of one-sided stitched laminated composites. 作者:Kristopher P. Plain 700
Matrix Methods in Data Mining and Pattern Recognition Second Edition 610
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 内科学 物理 复合材料 催化作用 细胞生物学 无机化学 光电子学 物理化学 电极 基因
热门帖子
关注 科研通微信公众号,转发送积分 7544248
求助须知:如何正确求助?哪些是违规求助? 9127958
关于积分的说明 19500295
捐赠科研通 7139216
什么是DOI,文献DOI怎么找? 3258673
关于科研通互助平台的介绍 2426013
邀请新用户注册赠送积分活动 2246869