医学
髂总动脉
髂内动脉
外科
髂外动脉
血运重建
试验装置豁免
动脉瘤
跛行
支架
放射科
前瞻性队列研究
髂动脉
腔内修复术
血管疾病
临床试验
腹主动脉瘤
动脉疾病
心脏病学
内科学
心肌梗塞
作者
Darren B. Schneider,Jon S. Matsumura,Jason T. Lee,Brian G. Peterson,Rabih A. Chaer,Gustavo S. Oderich
标识
DOI:10.1016/j.jvs.2022.07.006
摘要
We have reported the 5-year results of a pivotal prospective, multicenter study conducted in the United States of a specifically designed iliac branch endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, AZ) for endovascular repair of aortoiliac aneurysms and common iliac artery aneurysms.A total of 63 patients (98.4% male; mean age, 70 years) with aortoiliac or common iliac artery aneurysms had undergone implantation of a single IBE device and a bifurcated aortoiliac stent graft. Patients with bilateral common iliac artery aneurysms (n = 22; 34.9%) had undergone either staged occlusion or surgical revascularization of the contralateral internal iliac artery before study enrollment. At 5 years, 36 of the 63 patients had completed the final study follow-up examinations, including clinical examinations (n = 35) and computed tomography (n = 32), with the results evaluated by an independent core laboratory and adverse events adjudicated by a clinical events committee.At 5 years, freedom from all-cause mortality was 85.7% and freedom from aneurysm-related mortality was 100%. The nine deaths that had occurred (range, 132-1898 days) were adjudicated as unrelated to the aneurysm or procedure. Primary patency of the internal and external iliac artery IBE limbs was 95.1% and 100%, respectively. No patients had experienced new-onset buttock claudication on the IBE side or self-reported new-onset erectile dysfunction. The common iliac artery diameter on the IBE side was either unchanged or had decreased by ≥5 mm in 30 of the 31 patients (96.8%) with a baseline (1 month) and 5-year (range, 1641-2006 days) computed tomography scan available. Of the 31 evaluable patients, 9 (29.0%) had had an increase of ≥5 mm in the aortic diameter, 5 of whom had had a concurrent type II endoleak. No type I or type III endoleaks or device migration were identified by the core laboratory. Six patients had undergone eight secondary interventions, including five interventions for a type II endoleak. The freedom from secondary intervention was 90.5%.The 5-year results of our prospective, multicenter study have confirmed the safety, efficacy, and durability of the IBE device for the treatment of aortoiliac and iliac artery aneurysms. The device effectively prevented common iliac artery aneurysm rupture, maintained the patency of the internal iliac artery, and avoided the complications associated with internal iliac artery sacrifice. Although common iliac artery aneurysm enlargement was rare, abdominal aortic enlargement was more common, suggesting that the outcomes of endovascular aneurysm repair might be different for patients with or without associated common iliac artery aneurysms.
科研通智能强力驱动
Strongly Powered by AbleSci AI