Comparison of measures of ventricular delay on cardiac resynchronization therapy response

心脏再同步化治疗 医学 心脏病学 内科学 QRS波群 心室 束支阻滞 缺血性心肌病 左束支阻滞 右束支阻滞 优势比 射血分数 心力衰竭 心电图
作者
Michael E. Field,Nancy Yu,Nicholas Wold,Michael R. Gold
出处
期刊:Heart Rhythm [Elsevier BV]
卷期号:17 (4): 615-620 被引量:26
标识
DOI:10.1016/j.hrthm.2019.11.023
摘要

Background Left ventricular (LV) pacing at sites of prolonged LV delay (QLV) or at long interventricular delay (right ventricle [RV]-LV) is strongly associated with cardiac resynchronization therapy (CRT) response. QLV and RV-LV have been independently evaluated, but little is known regarding the interrelationship between these measures or of delay to the RV. Objective The purpose of this study was to evaluate the relationship between measures of electrical delay on CRT response in the SMART-AV (SmartDelay Determined AV Optimization: A Comparison to Other AV Delay Methods Used in Cardiac Resynchronization Therapy) trial. Methods In 419 patients, QLV and RV-LV were measured. CRT response was defined as a >15% reduction in LV end-systolic volume from implant to 6 months. The correlation between QLV and RV-LV and the clinical variables associated with the difference between QLV and RV-LV (QRV) were determined. Multivariable logistic regression was used to analyze the association between these measures on CRT response. A machine learning algorithm was used to construct a classification tree to predict response to CRT. Results The cohort was 66% male (age 66 ± 11 years), 75% had left bundle branch block; and QRS was 150 ± 25 ms. QLV and RV-LV were highly correlated (R2 = 0.71). A longer QRV was observed among patients with right bundle branch block, ischemic cardiomyopathy, and increased QRS. In a multivariable model including QLV, RV-LV, and other known predictors of CRT response, RV-LV, but not QLV, remained associated with CRT response (odds ratio 1.13; 95% confidence interval 1.02–1.26; P = .017). Combining the 2 measures achieved better prediction of CRT response in the group with intermediate RV-LV. Conclusion RV-LV is a better predictor of CRT response than QLV. There is incremental value in using both measurements or QRV in certain subpopulations. Left ventricular (LV) pacing at sites of prolonged LV delay (QLV) or at long interventricular delay (right ventricle [RV]-LV) is strongly associated with cardiac resynchronization therapy (CRT) response. QLV and RV-LV have been independently evaluated, but little is known regarding the interrelationship between these measures or of delay to the RV. The purpose of this study was to evaluate the relationship between measures of electrical delay on CRT response in the SMART-AV (SmartDelay Determined AV Optimization: A Comparison to Other AV Delay Methods Used in Cardiac Resynchronization Therapy) trial. In 419 patients, QLV and RV-LV were measured. CRT response was defined as a >15% reduction in LV end-systolic volume from implant to 6 months. The correlation between QLV and RV-LV and the clinical variables associated with the difference between QLV and RV-LV (QRV) were determined. Multivariable logistic regression was used to analyze the association between these measures on CRT response. A machine learning algorithm was used to construct a classification tree to predict response to CRT. The cohort was 66% male (age 66 ± 11 years), 75% had left bundle branch block; and QRS was 150 ± 25 ms. QLV and RV-LV were highly correlated (R2 = 0.71). A longer QRV was observed among patients with right bundle branch block, ischemic cardiomyopathy, and increased QRS. In a multivariable model including QLV, RV-LV, and other known predictors of CRT response, RV-LV, but not QLV, remained associated with CRT response (odds ratio 1.13; 95% confidence interval 1.02–1.26; P = .017). Combining the 2 measures achieved better prediction of CRT response in the group with intermediate RV-LV. RV-LV is a better predictor of CRT response than QLV. There is incremental value in using both measurements or QRV in certain subpopulations.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
bkagyin应助可可采纳,获得10
1秒前
芝芝莓莓应助躺平不摆烂采纳,获得10
1秒前
1秒前
涂丁元发布了新的文献求助10
2秒前
竹子完成签到,获得积分10
3秒前
一一发布了新的文献求助10
3秒前
jy完成签到,获得积分10
4秒前
6秒前
7秒前
8秒前
喻初彤发布了新的文献求助10
10秒前
柏铸海发布了新的文献求助10
10秒前
在水一方应助PZD采纳,获得10
11秒前
orixero应助半导体物理采纳,获得10
12秒前
12秒前
13秒前
NL14D发布了新的文献求助200
13秒前
长情的一刀完成签到,获得积分10
14秒前
852应助小陈采纳,获得10
14秒前
好旺发布了新的文献求助10
14秒前
一一完成签到,获得积分10
15秒前
ismm2002发布了新的文献求助10
17秒前
小二郎应助刻苦大侠采纳,获得10
19秒前
mzf发布了新的文献求助10
20秒前
现代的访曼应助XCHI采纳,获得20
24秒前
26秒前
26秒前
Duke完成签到,获得积分10
26秒前
漫漫完成签到 ,获得积分10
27秒前
华仔应助祯果粒采纳,获得10
27秒前
28秒前
量子星尘发布了新的文献求助10
28秒前
角鸮完成签到,获得积分10
29秒前
29秒前
PZD发布了新的文献求助10
29秒前
刻苦大侠发布了新的文献求助10
30秒前
31秒前
Guo1020181完成签到,获得积分10
31秒前
31秒前
乐乐应助科研通管家采纳,获得10
32秒前
高分求助中
The Mother of All Tableaux Order, Equivalence, and Geometry in the Large-scale Structure of Optimality Theory 2400
Ophthalmic Equipment Market by Devices(surgical: vitreorentinal,IOLs,OVDs,contact lens,RGP lens,backflush,diagnostic&monitoring:OCT,actorefractor,keratometer,tonometer,ophthalmoscpe,OVD), End User,Buying Criteria-Global Forecast to2029 2000
Optimal Transport: A Comprehensive Introduction to Modeling, Analysis, Simulation, Applications 800
Official Methods of Analysis of AOAC INTERNATIONAL 600
ACSM’s Guidelines for Exercise Testing and Prescription, 12th edition 588
T/CIET 1202-2025 可吸收再生氧化纤维素止血材料 500
Comparison of adverse drug reactions of heparin and its derivates in the European Economic Area based on data from EudraVigilance between 2017 and 2021 500
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 遗传学 基因 物理化学 催化作用 冶金 细胞生物学 免疫学
热门帖子
关注 科研通微信公众号,转发送积分 3952868
求助须知:如何正确求助?哪些是违规求助? 3498310
关于积分的说明 11091370
捐赠科研通 3228948
什么是DOI,文献DOI怎么找? 1785159
邀请新用户注册赠送积分活动 869202
科研通“疑难数据库(出版商)”最低求助积分说明 801377