医学
图像质量
核医学
图像噪声
神经组阅片室
对比噪声比
有效剂量(辐射)
辐射剂量
超声波
介入放射学
对比度(视觉)
血管造影
迭代重建
放射科
图像(数学)
神经学
人工智能
精神科
计算机科学
作者
Wanjiang Li,Kaiyue Diao,Yuting Wen,Shuai Tao,Yongchun You,Jin Zhao,Kai Liao,Chunyan Lu,Jianqun Yu,Yong He,Zhenlin Li
标识
DOI:10.1007/s00330-021-08424-5
摘要
To explore the use of 70-kVp tube voltage combined with high-strength deep learning image reconstruction (DLIR-H) in reducing radiation and contrast doses in coronary CT angiography (CCTA) in patients with body mass index (BMI) < 26 kg/m2, in comparison with the conventional scan protocol using 120 kVp and adaptive statistical iterative reconstruction (ASIR-V).A total of 100 patients referred to CCTA were prospectively enrolled and randomly divided into two groups: low-dose group (n = 50) with 70 kVp, Smart mA for noise index (NI) of 36HU, contrast dose rate of 16mgI/kg/s, and DLIR-H, and conventional group (n = 50) with 120 kV, Smart mA for NI of 25HU, contrast dose rate of 32mgI/kg/s, and 60%ASIR-V. Radiation and contrast dose, subjective image quality score, and objective image quality measurement (image noise, contrast-noise-ratio (CNR), and signal-noise-ratio (SNR) for vessel) were compared between the two groups.Low-dose group used significantly reduced contrast dose (23.82 ± 3.69 mL, 50.6% reduction) and radiation dose (0.75 ± 0.14 mSv, 54.5% reduction) compared to the conventional group (48.23 ± 6.38 mL and 1.65 ± 0.66 mSv, respectively) (all p < 0.001). Both groups had similar enhancement in vessels. However, the low-dose group had lower background noise (23.57 ± 4.74 HU vs. 35.04 ± 8.41 HU), higher CNR in RCA (48.63 ± 10.76 vs. 29.32 ± 5.52), LAD (47.33 ± 10.20 vs. 29.27 ± 5.12), and LCX (46.74 ± 9.76 vs. 28.58 ± 5.12) (all p < 0.001) compared to the conventional group.The use of 70-kVp tube voltage combined with DLIR-H for CCTA in normal size patients significantly reduces radiation dose and contrast dose while further improving image quality compared with the conventional 120-kVp tube voltage with 60%ASIR-V.• The combination of 70-kVp tube voltage and high-strength deep learning image reconstruction (DLIR-H) algorithm protocol reduces approximately 50% of radiation and contrast doses in coronary computed tomography angiography (CCTA) compared with the conventional scan protocol. • CCTA of normal size (BMI < 26 kg/m2) patients acquired at sub-mSv radiation dose and 24 mL contrast dose through the combination of 70-kVp tube voltage and DLIR-H algorithm achieves excellent diagnostic image quality with a good inter-rater agreement. • DLIR-H algorithm shows a higher capacity of significantly reducing image noise than adaptive statistical iterative reconstruction algorithm in CCTA examination.
科研通智能强力驱动
Strongly Powered by AbleSci AI