医学
甲状腺机能正常
内科学
内分泌学
免疫分析
连续稀释
抗体
抗甲状腺自身抗体
左旋甲状腺素
甲状腺
自身抗体
激素
促甲状腺激素
甲状腺球蛋白
免疫学
病理
替代医学
作者
Camilla Bøgelund Larsen,Eva Rabing Brix Petersen,Martin Overgaard,Steen Joop Bonnema
摘要
Analytical problems should be considered in case of a discrepancy between the results of biochemical tests and the clinical findings. Macro-hormones often artefactually elevate biochemical tests.A young male was referred with persistently elevated TSH (148 mIU/L) measured by a sandwich electrochemiluminescence immunoassay, ECLIA (Cobas; Roche, Basel, Switzerland). The patient's complaints were unspecific, and he appeared clinically euthyroid. The plasma levels of free T4 and free T3 were within the normal range, thyroid autoantibodies were negative, and thyroid ultrasonography was normal. During a short trial of thyroid hormone substitution, the level of TSH decreased to near-normal levels, but hyperthyroid symptoms emerged. TSH analysed by a different immunoassay (Architect; Abbott, Chicago, IL, USA) yielded similar results. In addition, serial dilutions were performed showing linearity, without detection of heterophilic antibody interference. Gel filtration chromatography confirmed the presence of macro-TSH.The patient harboured macro-TSH, which is a rare condition. The complex binding of TSH to other plasma proteins, most often immunoglobulins, results in elevated plasma TSH. However, the biologically active fraction of TSH is normal, reflected by clinical and biochemical euthyroidism.
科研通智能强力驱动
Strongly Powered by AbleSci AI