医学
艾普沃思嗜睡量表
阻塞性睡眠呼吸暂停
气道正压
随机对照试验
体质指数
呼吸暂停-低通气指数
物理疗法
持续气道正压
医院焦虑抑郁量表
呼吸暂停
睡眠呼吸暂停
多导睡眠图
内科学
焦虑
儿科
精神科
作者
Benedikt Fridriksson,Marianne Berndtson,Henrik Hamnered,Erik Faeder,Ding Zou,Jan Hedner,Ludger Grote
出处
期刊:Annals of the American Thoracic Society
[American Thoracic Society]
日期:2023-10-01
卷期号:20 (10): 1499-1507
被引量:1
标识
DOI:10.1513/annalsats.202208-723oc
摘要
Rationale: Positive airway pressure (PAP) is standard treatment for obstructive sleep apnea. Telemedicine has been introduced for improved PAP follow-up. Objectives: Our study aim was to evaluate the clinical utility of and patient satisfaction with PAP follow-up with an early intervention telemedical protocol. Methods: A randomized controlled trial was conducted at four sleep clinics of the same county. Treatment-naive patients with obstructive sleep apnea were randomized to standard PAP follow-up (203 patients, fixed follow-up procedures) or early intervention telemedical follow-up (AirView, ResMed; 206 patients, continuous follow-up) for 3 months. Evaluated variables included PAP adherence at 3 months, patient-reported outcome measures (Epworth Sleepiness Scale, 36-item Short Form Health Survey, Insomnia Severity Index, Hospital Anxiety and Depression Scale), and staff time. Group differences were analyzed with linear mixed regression models adjusted for age, body mass index, apnea-hypopnea index, and study center. Results: The study groups were comparable at baseline (N = 409; mean age, 59 ± 12 yr; body mass index, 31.9 ± 6 kg/m2, apnea-hypopnea index, 41.5 ± 21 events/h). PAP adherence was higher in the proactive telemedicine group than in the control group (4.3 ± 2.4 and 4.1 ± 2.6 h/night; P = 0.01, respectively), and mean mask pressure at follow-up was significantly lower in the telemedicine group than in the control group (8.7 ± 2.1 cm H2O vs. 9.2 ± 2.5 cm H2O; P = 0.028). In post hoc analysis, the difference in PAP adherence between groups was most pronounced in patients with depression (4.8 ± 2.6 h/night vs. 2.7 ± 2.3 h/night; P = 0.03). Relevant mask leakage (>24 L/min) was lower in the telemedicine group (5.4% vs. 12.1%, P = 0.024). Improvement of patient-reported outcome measures and patient satisfaction was equivalent between groups. Conclusions: Proactive telemedical management of the initial follow-up of PAP treatment compared favorably with conventional follow-up in terms of adherence, pressure level, and mask leakage. Patients with depression may particularly benefit from telemedical follow-up. Specific clinical routines are required to establish this practice in sleep clinics. Clinical trial registered with www.clinicaltrials.gov (NCT03446560).
科研通智能强力驱动
Strongly Powered by AbleSci AI