A Biomechanical Comparison of Alternative Graft Preparations for All-Inside Anterior Cruciate Ligament Reconstruction

固定(群体遗传学) 前交叉韧带 生物力学 流离失所(心理学) 解剖 外科 医学 心理学 人口 环境卫生 心理治疗师
作者
Meghan W. Richardson,Nicholas Tsouris,Chaudhry Raza Hassan,Justen Elbayar,Yi‐Xian Qin,David E. Komatsu,Angelo Rizzi,James M. Paci
出处
期刊:Arthroscopy [Elsevier BV]
卷期号:35 (5): 1547-1554 被引量:10
标识
DOI:10.1016/j.arthro.2018.11.065
摘要

Purpose To biomechanically compare alternative graft constructs for all-inside anterior cruciate ligament (ACL) reconstruction in the event that the semitendinosus harvested is too narrow or too short to make a graft larger than 8 mm. Methods Bovine extensor tendons were used to make 6 different 9-mm-diameter grafts: traditional 4-strand, anastomosis 4-strand, 6-strand, 3-strand, button-fixation 4-strand, and loop-and-tack 4-strand grafts. The grafts were then subjected to cyclic biomechanical testing followed by failure loading. Force at 3 and 5 mm of displacement and ultimate force were recorded for all grafts. Results Compared with the traditional 4-strand graft, the only graft that showed significant biomechanical differences during the cyclic phase of testing was the button-fixation 4-strand graft, which was characterized by lower force at 3 mm of displacement (74 ± 34 N vs 122 ± 13 N, P = .004) and 5 mm of displacement (122 ± 35 N vs 172 ± 3 N, P = .006). During failure loading, ultimate force was significantly lower for both the 6-strand graft (491 ± 186 N, P = .041) and button-fixation 4-strand graft (326 ± 27 N, P < .001) than for the traditional 4-strand graft (778 ± 176 N). All other grafts were equivalent for the parameters tested. Conclusions The anastomosis 4-strand, 3-strand, and loop-and-tack 4-strand grafts do not biomechanically differ in cyclic loading and ultimate force from traditional 4-strand grafts. This study supports the use of anastomosis 4-strand, 3-strand, or loop-and-tack 4-strand grafts in the event that a traditional all-inside 4-strand graft cannot be prepared from a harvested semitendinosus tendon in ACL reconstruction. Clinical Relevance This study tests and describes alternatives to the traditional 4-strand semitendinosus autograft for all-inside ACL reconstruction in the event that the harvested tendon is not adequate. To biomechanically compare alternative graft constructs for all-inside anterior cruciate ligament (ACL) reconstruction in the event that the semitendinosus harvested is too narrow or too short to make a graft larger than 8 mm. Bovine extensor tendons were used to make 6 different 9-mm-diameter grafts: traditional 4-strand, anastomosis 4-strand, 6-strand, 3-strand, button-fixation 4-strand, and loop-and-tack 4-strand grafts. The grafts were then subjected to cyclic biomechanical testing followed by failure loading. Force at 3 and 5 mm of displacement and ultimate force were recorded for all grafts. Compared with the traditional 4-strand graft, the only graft that showed significant biomechanical differences during the cyclic phase of testing was the button-fixation 4-strand graft, which was characterized by lower force at 3 mm of displacement (74 ± 34 N vs 122 ± 13 N, P = .004) and 5 mm of displacement (122 ± 35 N vs 172 ± 3 N, P = .006). During failure loading, ultimate force was significantly lower for both the 6-strand graft (491 ± 186 N, P = .041) and button-fixation 4-strand graft (326 ± 27 N, P < .001) than for the traditional 4-strand graft (778 ± 176 N). All other grafts were equivalent for the parameters tested. The anastomosis 4-strand, 3-strand, and loop-and-tack 4-strand grafts do not biomechanically differ in cyclic loading and ultimate force from traditional 4-strand grafts. This study supports the use of anastomosis 4-strand, 3-strand, or loop-and-tack 4-strand grafts in the event that a traditional all-inside 4-strand graft cannot be prepared from a harvested semitendinosus tendon in ACL reconstruction.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
CT民工发布了新的文献求助10
刚刚
受伤冰菱完成签到,获得积分10
1秒前
lingyu完成签到,获得积分10
1秒前
2秒前
南絮发布了新的文献求助10
2秒前
ccc完成签到,获得积分10
2秒前
2秒前
2秒前
武工队队长石青山完成签到,获得积分10
2秒前
量子星尘发布了新的文献求助10
4秒前
4秒前
4秒前
4秒前
卷儿w发布了新的文献求助40
5秒前
陆程文发布了新的文献求助10
5秒前
MXG完成签到,获得积分10
5秒前
隐形曼青应助ornot君君采纳,获得10
6秒前
zhulinkin完成签到 ,获得积分10
6秒前
睡醒了发布了新的文献求助10
7秒前
米鼓完成签到 ,获得积分10
8秒前
8秒前
科研发布了新的文献求助30
8秒前
青年才俊发布了新的文献求助30
9秒前
清脆的乌冬面完成签到,获得积分10
9秒前
9秒前
大模型应助芝麻球ii采纳,获得10
9秒前
WANG完成签到 ,获得积分10
9秒前
10秒前
myf完成签到,获得积分20
10秒前
10秒前
taiping发布了新的文献求助10
10秒前
幽悠梦儿完成签到,获得积分10
11秒前
解冰珍完成签到,获得积分10
11秒前
12秒前
无聊的访枫完成签到 ,获得积分10
12秒前
12秒前
斯文败类应助科研通管家采纳,获得10
13秒前
GuoSiqi72应助科研通管家采纳,获得10
13秒前
iNk应助科研通管家采纳,获得30
13秒前
科研通AI5应助科研通管家采纳,获得10
13秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Acute Mountain Sickness 2000
A novel angiographic index for predicting the efficacy of drug-coated balloons in small vessels 500
Textbook of Neonatal Resuscitation ® 500
Thomas Hobbes' Mechanical Conception of Nature 500
The Affinity Designer Manual - Version 2: A Step-by-Step Beginner's Guide 500
Affinity Designer Essentials: A Complete Guide to Vector Art: Your Ultimate Handbook for High-Quality Vector Graphics 500
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 内科学 生物化学 物理 计算机科学 纳米技术 遗传学 基因 复合材料 化学工程 物理化学 病理 催化作用 免疫学 量子力学
热门帖子
关注 科研通微信公众号,转发送积分 5097313
求助须知:如何正确求助?哪些是违规求助? 4309783
关于积分的说明 13428428
捐赠科研通 4137300
什么是DOI,文献DOI怎么找? 2266533
邀请新用户注册赠送积分活动 1269654
关于科研通互助平台的介绍 1205978