结垢
氯
生物污染
膜污染
反渗透
膜
化学
胞外聚合物
废水
细菌
微生物学
色谱法
环境化学
环境工程
生物
生物化学
有机化学
环境科学
生物膜
遗传学
作者
Li-Wei Luo,Yin-Hu Wu,Genqiang Chen,Haobin Wang,Yunlong Wang,Xin Tong,Yuan Bai,Yuan Xu,Ziwei Zhang,Nozomu Ikuno,Hong-Ying Hu
出处
期刊:Water Research
[Elsevier]
日期:2022-02-01
卷期号:209: 117966-117966
被引量:7
标识
DOI:10.1016/j.watres.2021.117966
摘要
Chlorine disinfection is often used as a pretreatment technology to control biofouling of reverse osmosis (RO) membranes. However, previous studies showed that biofouling of the RO system was aggravated after chlorine disinfection. Chlorine-resistant bacteria (CRB) were presumed to be closely related to the aggravation of fouling caused by chlorine disinfection. In order to analyze the membrane fouling mechanisms of CRB, 5 CRB strains were isolated from the surface of fouled RO membranes for wastewater reclamation, and 3 reference bacterial strains, Sphingopyxis soli BM1-1, Pseudomonas aeruginosa PAO1 and Escherichia coli CGMCC1.3373, were selected for comparative study. The chlorine resistance, membrane fouling potential, secretion and adhesion characteristics of these strains were evaluated. Among these isolated strains, 3 strains showed much higher chlorine resistance than PAO1 under the condition of 0.5, 2, 5 mg/L-Cl2, especially Bacillus CR19 and Bacillus CR2. Furthermore, a significant positive correlation was found between membrane fouling potential and chlorine resistance of all the strains in this study. The membrane fouling potential of the above 8 strains increased monotonically with the increase of chlorine resistance (under the condition of 0.5 mg/L-Cl2). Serious fouling caused by extracellular substances was observed in biofouling layers of the strains with high chlorine resistance, which lead to more severe flux decline. Extracellular polymeric substances (EPS) amount per cell was found to be the main factor related to the chlorine resistance as well as the fouling potential. Computational fluid dynamics (CFD) simulation was used to demonstrate the filtration resistance induced by the secretion of EPS. However, CRB with higher EPS amount may not show higher membrane adhesion potential, and thus may not be the dominant strain on the RO membranes before chlorine disinfection. These CRB with high fouling potential but low membrane adhesion potential, such as Bacillus CR19 and Bacillus CR2, may become the dominant bacteria on the membrane surface after chlorine disinfection and thus aggravate membrane fouling significantly.
科研通智能强力驱动
Strongly Powered by AbleSci AI