透皮
双膦酸盐
生物利用度
吸收(声学)
骨质疏松症
生物医学工程
材料科学
药理学
医学
化学
复合材料
内科学
作者
Hidemasa Katsumi,Shu Liu,Yutaro Tanaka,Kaori Hitomi,Rie Hayashi,Yuka Hirai,Kosuke Kusamori,Ying-Shu Quan,Fumio Kamiyama,Toshiyasu Sakane,Akira Yamamoto
摘要
Alendronate is a nitrogen-containing bisphosphonate that is widely used for the treatment of osteoporosis. In this study, we developed a novel self-dissolving micron-size needle array (microneedle array) containing alendronate, which was fabricated by micromodeling technologies using hyaluronic acid as a basic material. Micron-scale pores in the skin were seen after the application of the alendronate-loaded microneedle array, verifying establishment of transdermal pathways for alendronate. The absorption of alendronate after the application of alendronate-loaded microneedle array was almost equivalent to that after subcutaneous administration, and the bioavailability of alendronate was approximately 90% in rats. Furthermore, delivery of alendronate via this strategy effectively suppressed the decrease in the width of the growth plate in a rat model of osteoporosis. Although mild cutaneous irritation was observed after the application of the alendronate-loaded microneedle array, it resolved by day 15. These findings indicate that this alendronate-loaded microneedle array is a promising transdermal formulation for the treatment of osteoporosis. © 2012 Wiley Periodicals, Inc. and the American Pharmacists Association. Alendronate is a nitrogen-containing bisphosphonate that is widely used for the treatment of osteoporosis. In this study, we developed a novel self-dissolving micron-size needle array (microneedle array) containing alendronate, which was fabricated by micromodeling technologies using hyaluronic acid as a basic material. Micron-scale pores in the skin were seen after the application of the alendronate-loaded microneedle array, verifying establishment of transdermal pathways for alendronate. The absorption of alendronate after the application of alendronate-loaded microneedle array was almost equivalent to that after subcutaneous administration, and the bioavailability of alendronate was approximately 90% in rats. Furthermore, delivery of alendronate via this strategy effectively suppressed the decrease in the width of the growth plate in a rat model of osteoporosis. Although mild cutaneous irritation was observed after the application of the alendronate-loaded microneedle array, it resolved by day 15. These findings indicate that this alendronate-loaded microneedle array is a promising transdermal formulation for the treatment of osteoporosis. © 2012 Wiley Periodicals, Inc. and the American Pharmacists Association. HAhyaluronic acidQOLquality of lifeAUCarea under the concentration–time curveBAbioavailabilityOVXovariectomyTEWLtrans-epidermal water loss. hyaluronic acid quality of life area under the concentration–time curve bioavailability ovariectomy trans-epidermal water loss.
科研通智能强力驱动
Strongly Powered by AbleSci AI