亲爱的研友该休息了!由于当前在线用户较少,发布求助请尽量完整的填写文献信息,科研通机器人24小时在线,伴您度过漫漫科研夜!身体可是革命的本钱,早点休息,好梦!

A Microfluidic System for Controlling Reaction Networks in Time

微流控 毫秒 混合(物理) 色散(光学) 度量(数据仓库) 机械 生物系统 物理 材料科学 纳米技术 计算机科学 光学 量子力学 天文 数据库 生物
作者
Helen Song,Joshua D. Tice,Rustem F. Ismagilov
出处
期刊:Angewandte Chemie [Wiley]
卷期号:42 (7): 768-772 被引量:1022
标识
DOI:10.1002/anie.200390203
摘要

Angewandte Chemie International EditionVolume 42, Issue 7 p. 768-772 CommunicationFree Access A Microfluidic System for Controlling Reaction Networks in Time† Helen Song, Helen Song Department of Chemistry, The University of Chicago, 5735 S. Ellis Avenue, Chicago, IL 60637, USA, Fax: (+1) 773-702-0805Search for more papers by this authorJoshua D. Tice, Joshua D. Tice Department of Chemistry, The University of Chicago, 5735 S. Ellis Avenue, Chicago, IL 60637, USA, Fax: (+1) 773-702-0805Search for more papers by this authorRustem F. Ismagilov Prof., Rustem F. Ismagilov Prof. r-ismagilov@uchicago.edu Department of Chemistry, The University of Chicago, 5735 S. Ellis Avenue, Chicago, IL 60637, USA, Fax: (+1) 773-702-0805Search for more papers by this author Helen Song, Helen Song Department of Chemistry, The University of Chicago, 5735 S. Ellis Avenue, Chicago, IL 60637, USA, Fax: (+1) 773-702-0805Search for more papers by this authorJoshua D. Tice, Joshua D. Tice Department of Chemistry, The University of Chicago, 5735 S. Ellis Avenue, Chicago, IL 60637, USA, Fax: (+1) 773-702-0805Search for more papers by this authorRustem F. Ismagilov Prof., Rustem F. Ismagilov Prof. r-ismagilov@uchicago.edu Department of Chemistry, The University of Chicago, 5735 S. Ellis Avenue, Chicago, IL 60637, USA, Fax: (+1) 773-702-0805Search for more papers by this author First published: 17 February 2003 https://doi.org/10.1002/anie.200390203Citations: 790 † This work was supported by the Camille and Henry Dreyfus New Faculty Award Program, the Searle Scholars Program, an award from Research Corporation, the Chicago MRSEC funded by the NSF. H.S. was supported by a Predoctoral Training Grant of the NIH (GM 08720). We thank our colleagues at the University of Chicago for invaluable discussions and suggestions. We thank Prof. Sidney Nagel, in addition, for an equipment loan and Ian Hawkins for measuring surface tensions. Photolithography was performed by H.S. at MAL of the University of Illinois at Chicago. Microscopy was conducted at the University of Chicago Cancer Center Digital Light Microscopy Facility. AboutSectionsPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onFacebookTwitterLinked InRedditWechat Abstract Millisecond mixing and transport with no dispersion are achieved by unsteady flows induced in droplets of about 60 pL that travel through winding microfluidic channels (top). Fluorescence can be used to monitor mixing (bottom) or measure reaction rates. In principle, arbitrarily complex reaction networks can be created by combining and splitting streams of such droplets. We present here a microfluidic system that may be used to control networks of many chemical reactions on the millisecond scale. It allows to control when each reaction begins, for how long each reaction evolves before it is separated or combined with other reactions, and when each reaction is analyzed or quenched. The system uses flow of fluids to linearly transform space (length of capillaries) into time (reaction time). For a chemical reaction in an open system this transformation is simple and well known: A solution of reagent A and a solution of reagent B are injected as steady streams into a microfluidic channel at initial point d=0 where the reaction between them begins (t=0). As the reaction mixture is transported by the fluid stream at a constant velocity U, every spatial point d corresponds to a time point t, the reaction time, where t=d/U. If such a system is implemented, interactions of multiple chemical reactions in time could be controlled simply by creating a network of converging and diverging channels carrying reaction mixtures, and varying flow velocities to adjust reaction and interaction times. If the reactions are accompanied by an optical signal (e.g. changes in fluorescence or absorption), time-resolved measurements of the reactions in the entire network could be obtained from a single spatially resolved optical image. Networks of microfluidic channels1–3 are especially attractive for this distance-to-time transformation because they can be easily fabricated and used to manipulate small volumes of reagents; they are becoming essential for chemical and biological analysis and synthesis.1–3 Flow in microfluidic devices is laminar; it occurs at low values of the Reynolds number, Re (∼0.01–100). Re is defined as l Uρ/μ, where l [m] is the diameter of the capillary, U [m s−1] the velocity of the flow, ρ [kg m−3] the density, and μ [kg m−1 s−1] the viscosity of the fluid.4 This laminar flow makes it difficult to implement the distance-to-time transformation in microfluidic devices for two reasons (Figure 1 a). First, mixing is slow—two streams injected into a channel flow side-by-side with mixing only by diffusion,4–6 therefore d=0 does not correspond to a well-defined starting point (t=0) of the reaction. Significant research efforts have been devoted to solving this problem of slow mixing.2, 3, 7 Turbulent flows provide both rapid mixing and low dispersion,8 but turbulence occurs at values of Re>2000 reached in microchannels only at high flow rates (∼10 m s−1). Achieving such flow velocities requires undesirably high sample consumption (∼1 mL s−1) and high pressures. Second, the dispersion of solutes along the channel is large—the flow profile is parabolic, and the reagents are transported at a range of velocities.4 Therefore, a given distance d corresponds to a range of reaction times t=d/U. Figure 1Open in figure viewerPowerPoint Schematic comparison of a reaction A+B conducted in a standard pressure-driven microfluidic system device (a) and in the microfluidic device described here (b). a) Reaction time t≠d/U. b) Reaction time t=d/U. Two aqueous reagents (red, A and blue, B) can form laminar streams separated by a gray “divider” aqueous stream in a microchannel. When the three streams enter the channel with a flowing immiscible fluid, they form droplets (plugs). The reagents come into contact as the contents of the droplets are rapidly mixed. Internal recirculation within plugs flowing through channels of different geometries is shown schematically by arrows. We developed a simple microfluidic system that overcomes both problems—it transports solutions with rapid mixing and no dispersion (Figure 1 b). This system uses networks of microchannels with rectangular cross sections and hydrophobic surfaces fabricated using rapid prototyping in polydimethylsiloxane (PDMS).9 We controlled the volumetric flow rates through each channel using syringe pumps. Dispersion was eliminated by localizing the reagents within aqueous plugs (droplets large enough to block the channel) separated by a water-immiscible oil. Immiscible fluids have been used to localize reagents in both commercial10 and laboratory11–13 systems. Here we describe methods for forming plugs of multiple solutions of reagents, for using chaotic advection to achieve especially rapid (∼2 ms) mixing within the plugs, and for splitting and merging these plugs in order to create complex microfluidic networks. To form droplets from two solutions of reagents without bringing the reagents into prior contact we flowed these solutions in a microchannel as two laminar streams,14 and used an inert center stream to separate them. These three streams were continuously injected into a flow of water-immiscible perfluorodecaline (PFD) in the main microchannel, where they spontaneously broke up into streams of plugs (∼500 pL) separated and surrounded by PFD (Figure 2). Diffusion through the central stream was too slow for the reagents in the two side streams to interact prior to the formation of a plug. Plugs of three or more reagents could be formed in the same manner. PFD is an attractive choice of carrier fluid because it is inert, immiscible with water and organic solvents, and does not swell PDMS. Emulsions of perfluorocarbons such as PFD are used as blood substitutes in humans during surgeries15 and should be compatible with a range of biological molecules. We controlled the wetting of PDMS by PFD by adding 9 % v/v of C6F11C2H4OH to PFD. Water-in-oil emulsions are known to form in pressure-driven flow in microchannels,16, 17 often at high values of the dimensionless capillary number, Ca (Ca=U μ/γ, γ [N m−1]: surface tension at the PFD/water interface).18 Our system was operated at low values of Ca because at high values of Ca, the shear flow broke up the aqueous phase into small droplets that did not block the channels and were not transported reliably over long distances. Complex behavior in this latter regime has been carefully characterized.16 Figure 2Open in figure viewerPowerPoint Spontaneous formation of uniform plugs out of multiple aqueous streams. Left: Schematic diagram of the microchannel network. Volumetric flow rates for all streams (in μL min−1) are given in parenthesis. Middle: Microphotograph (10 μs exposure) of plug formation and transport. Right: Magnified microphotographs (10 μs exposure) of the plug-forming region at different time points. All microchannels had 50×50 μm2 cross sections. Total flow rate in the main channel: 7.5 μL min−1 (50 mm s−1 average flow velocity); Re∼2.5 (water), ∼0.93 (PFD). PFD here stands for a 10:1 mixture of perfluorodecaline and C6F11C2H4OH. Red stream: solution of [Fe(SCN)x](3−x)+ prepared by mixing 0.067 M Fe(NO3)3 with 0.2 M KSCN; colorless streams: 0.2 M KNO3. A plug moving in a straight channel generates a steady, recirculating flow.19 This flow mixes the fluid within the left and the right (along the direction of the flow) halves of the plug (black arrows in Figure 1 b, right1), but not between the two halves. Laminar flow is preserved during plug formation that occurs at low Re; the reagent solutions end up in the two halves of the plug, and internal recirculation within elongated plugs enhances mixing only moderately (Figure 2). Chaotic advection accelerates mixing by using unsteady fluid flow to stretch and fold a volume of fluid. Stretching and folding leads to a rapid, exponential decrease of the striation length—distance over which mixing has to occur by diffusion. At intermediate Re (Re∼70), chaotic advection can be generated in three-dimensional microfluidic systems.20 An elegant system used asymmetric ridges on the floor of a microchannel to induce chaotic advection at both low and intermediate values of Re (Re=0–100).7 Here we show how the principles of chaotic advection can be applied to mixing inside plugs. The principle of chaotic advection has been illustrated with flow-cavity experiments.21 In a flow cavity, motion of the top and bottom walls induces flow within a volume of fluid. Simultaneous motion of these walls induces steady flow that mixes solutions slowly (Figure 3 a). Time-periodic, alternating motion of the walls induces unsteady, chaotic flow that mixes solutions rapidly (Figure 3 b). Crossing of streamlines in this time-periodic flow is a necessary condition for chaos.21 Figure 3Open in figure viewerPowerPoint Mixing by steady (a) and time-periodic (b) flows in flow cavities. a, b) Top: Schematic illustration of the flow cavity. The vertical walls are stationary and the horizontal walls move as shown. Bottom: Images (reprinted with permission of Cambridge University Press from ref. 21) that illustrate the flow patterns. For details, see text. Fluid flow in a flow cavity is similar to fluid flow in a plug moving inside a channel, except for the frame of reference—in a flow cavity walls move relative to the fluid, and in a plug fluid moves relative to the walls. Steady flow in a flow cavity is similar to steady, recirculating flow in plugs moving in a straight channel (black arrows in Figure 1 b right1). For arbitrary initial conditions, mixing by this steady flow is inefficient (efficiency decreases as 1/t)19, 21 because solutes become trapped on the streamlines that do not cross.21 For example, this flow mixes the contents within the left and right halves of the plug, but not between the two halves (Figure 2). The two-dimensional component of this flow responsible for mixing of the solutions can be envisioned as two counter-rotating vortices located in the left and right halves of the plug (white arrows in Figure 1 b). In the flow cavity shown in Figure 3 the two vortices are co-rotating. Pairs of co-22–24 and counter-rotating24, 25 vortices both generate chaos in periodic time-dependent flow. We induced such a flow in plugs by replacing a straight channel with a winding channel (Figure 4). A plug moving through a curved part of the winding channel is moving at different velocities relative to the two walls, similar to fluid in a flow cavity of Figure 3 b. We have deduced the streamlines shown by the white arrows in Figure 1 b by observing asymmetric plugs traveling through curved channels; these streamlines are similar to those shown in Figure 3 b. In plugs moving through winding channels we observed flow patterns that corresponded to very rapid mixing (Figure 4 a). These flow patterns were reproducible, and were similar for plugs moving at different speeds, except for some blurring by diffusion at lower speeds. At these low values of Re, winding channels did not accelerate mixing in laminar flow in the absence of PFD (Figure 4 b). Figure 4Open in figure viewerPowerPoint a), b) Microphotographs (10 μs exposure) illustrating rapid mixing inside plugs (a) and negligible mixing in a laminar flow (b) moving through winding channels at the same total flow velocity; same solutions as for Figure 2. c) A false-color microphotograph (2 s exposure, individual plugs are invisible) showing time-averaged fluorescence arising from rapid mixing inside plugs of solutions of Fluo-4 (54 μM) and CaCl2 (70 μM) in aqueous sodium morpholine propanesulfonate buffer (20 mM, pH 7.2); this buffer was also used as the middle aqueous stream. d) Relative normalized intensity (I) of fluorescence obtained from images such as shown in (c) as a function of distance (left) traveled by the plugs and of time required to travel that distance (right) at a given flow rate. The total intensity across the width of the channel was measured. Total PFD/water volumetric flow rates (in μL min−1) were • 0.6:0.3, • 1.0:0.6, • 12.3:3.7, • 10:6, • 20:6. e) A false-color microphotograph (2 s exposure) of the weak fluorescence arising from negligible mixing in a laminar flow of the solutions used in (c). All channels were 45 μm deep; inlet channels were 50 μm and winding channels 28 μm wide; Re∼5.3 (water), ∼2.0 (PFD). In Figure 4 c, d4 we show that this system can be used to measure the rates of chemical reactions on the millisecond time scale, and that these rates can be used to quantify mixing.6 This was done by measuring the rate of rapid binding (kon=7.1×108 M−1 s−1)26 of Ca2+ ions to the calcium-sensitive dye fluo-4 (Figure 4 c). Fluo-4 is weakly fluorescent in the absence of calcium whereas the complex fluo-4⋅Ca2+ shows strong fluorescence; accordingly, increase in fluorescence corresponds to mixing. At every flow rate we obtained a complete time-resolved reaction profile by acquiring a single spatially resolved long-exposure image of the fluorescence.8 Each image was integrated over two seconds to give the average fluorescence intensity of hundreds of moving plugs (∼60 pL in volume) and non-fluorescent PFD, and consumed less than 50 nL of fluo-4 solution. For the laminar flow of these solutions in the absence of PFD only weak fluorescence was observed (Figure 4 e) consistent with negligible mixing shown in Figure 4 b. Mixing of CaCl2 and fluo-4 solutions in the plugs was achieved within a short distance (∼500 μm, Figure 4 d), which was not very sensitive to the PFD/water ratio, and was weakly dependent on flow velocity. At higher flow rates it corresponded to mixing in about 2 ms (Figure 4 d). These facts and the flow patterns in Figure 4 a are consistent with chaotic mixing, but detailed modeling would be required to identify the chaotic regions within the plugs. Such modeling would have to account for the three-dimensional recirculation within both aqueous plugs and PFD in a given geometry and should suggest the geometry of the winding channels—symmetric or asymmetric, regular or random—required for most efficient mixing. A key attractive feature of microfluidics is the possibility of creating large fluidic networks.27 To demonstrate how, in principle, a network with complex connectivity could be created with this system we designed methods for combining two streams of plugs into a single stream in a main channel (merging plugs), and for dividing one stream of plugs into two streams (splitting plugs). Merging was rare when the main channel was of the same width as the channels in which the plugs formed as plugs merged only if they entered the main channel simultaneously (in phase). Plugs that entered out of phase continued through the main channel separated by PFD because they all moved at the same constant velocity. By contrast, merging was achieved in a wide main channel, even for streams of plugs that were out of phase (Figure 5 a). We formed small and large plugs in 30-μm and 60-μm wide channels, respectively. These plugs did not block the expanded 100-μm wide main channel and could move at two different velocities until they coalesced.28 Small droplets moved more slowly than large droplets;16 this effect is well known and is the basis of hydrodynamic chromatography.29 Sufficiently large fluctuations in the relative flow rates in the two channels disrupted merging, but more than 95 % of the plugs merged correctly when flows were simply driven with pressure of compressed air from a house line, regulated manually. Figure 5Open in figure viewerPowerPoint a) Spontaneous merging of pairs of plugs into single plugs. Left: schematic diagram of the microfluidic network; right: microphotograph of two streams of plugs merging in a main microchannel. b) Spontaneous splitting of plugs at a branching point in a microchannel. Left: schematic diagram of the microchannel network and the experimental conditions used. Middle: microphotograph showing splitting of a stream of plugs into plugs of approximately one-half the volume of the initial plugs. The outlet pressures were equal for the two channels. Right: asymmetric splitting of both aqueous and PFD plugs occurred when hydrostatic pressure of about 6 kPa was applied to the second outlet. a), b) Volumetric PFD/water flow rate ratios, flow velocities, and cross-sectional dimensions of the channels (width×height) are also shown. Reliable splitting of plugs at branching points of microchannels was achieved by constricting the channels at the branching points. When the channels were not constricted, short rounded plugs often showed a complicated behavior dominated by the surface tension at the PFD/water interfaces. In constricted channels the plugs became long and narrow and behaved simply like laminar flows subjected to pressure gradients (Figure 5 b). The size of the split plugs was proportional to the relative flow rates in the two outlet channels; we controlled these flow rates by varying the relative hydrostatic pressures at the two outlets. Splitting and subsequent merging of plugs could become useful for high-throughput parallel measurements. These methods of merging and splitting rely on a simple control of widths of channels and should become especially useful in combination with advanced methods of pumping.30 Overall, the phenomena described here allow us to construct a microfluidic system that linearly converts distance into time by achieving millisecond mixing and transport with no dispersion. We believe that it will be useful for both chemical analysis and synthesis, and for studies of complex reaction networks.31 The system is easy to fabricate and operate, has no active or moving components, and can be controlled simply by varying the rates of fluid flow. The uncertainty of the distance-to-time transformation is limited by the mixing distance. Both short (ms) and long (min) time scales can be accessed in the same microfluidic device simply by varying the flow velocity. Sub-millisecond time scales should be accessible by decreasing the size of the channels, and by increasing the flow rate (as long as the capillary number remains small). In a serpentine microfluidic network an entire time course of a chemical reaction can be obtained with millisecond resolution by analyzing fluorescence from a single image. Because the flows are steady this image does not have to be time-resolved8 and can be obtained with long exposures of a CCD or even a photographic camera. This system consumes samples at a rate about 10 000 times lower (μL min−1) than devices that rely on turbulence for mixing (mL s−1). It may serve a broad community of chemists, biochemists, and biophysicists as an inexpensive compliment to stop-flow instruments. In addition to a planar, trivial to fabricate, disposable plastic chip it only requires equipment already present in most laboratories: a source of pressure, such as a syringe pump or a cylinder of compressed gas, and a microscope with a CCD camera. We believe that this system for conducting reactions in sub-nanoliter plugs will also become valuable in traditional areas of microfluidics where miniaturization and speed are important—for example, high-throughput screening, combinatorial synthesis, analysis, and diagnostics—both as a self-contained platform, and in combination with the existing technologies, especially those using flows of immiscible fluids.32, 33 References 1M. A. Burns, Science 2002, 296, 1818. CrossrefCASPubMedWeb of Science®Google Scholar 2P.-A. Auroux, D. Iossifidis, D. R. Reyes, A. Manz, Anal. Chem. 2002, 74, 2623. CrossrefCASPubMedGoogle Scholar 3P.-A. Auroux, D. Iossifidis, D. R. Reyes, A. Manz, Anal. Chem. 2002, 74, 2637. CrossrefCASPubMedWeb of Science®Google Scholar 4R. B. Bird, W. E. Stewart, E. N. Lightfoot, Transport Phenomena, Wiley, New York, 2002. CrossrefGoogle Scholar 5A. E. Kamholz, P. Yager, Sens. Actuators B 2002, 82, 117. CrossrefCASWeb of Science®Google Scholar 6R. F. Ismagilov, A. D. Stroock, P. J. A. Kenis, G. Whitesides, H. A. Stone, Appl. Phys. Lett. 2000, 76, 2376. CrossrefCASWeb of Science®Google Scholar 7A. D. Stroock, S. K. W. Dertinger, A. Ajdari, I. Mezic, H. A. Stone, G. M. Whitesides, Science 2002, 295, 647. CrossrefCASPubMedWeb of Science®Google Scholar 8M. C. R. Shastry, S. D. Luck, H. Roder, Biophys. J. 1998, 74, 2714. CrossrefCASPubMedWeb of Science®Google Scholar 9J. C. McDonald, D. C. Duffy, J. R. Anderson, D. T. Chiu, H. K. Wu, O. J. A. Schueller, G. M. Whitesides, Electrophoresis 2000, 21, 27. Wiley Online LibraryCASPubMedWeb of Science®Google Scholar 10D. D. Cunningham, Anal. Chim. Acta 2001, 429, 1. CrossrefCASWeb of Science®Google Scholar 11M. A. Burns, B. N. Johnson, S. N. Brahmasandra, K. Handique, J. R. Webster, M. Krishnan, T. Sammarco, P. M. Man, D. Jones, D. Heldsinger, C. H. Mastrangelo, D. T. Burke, Science 1998, 282, 484. CrossrefCASPubMedWeb of Science®Google Scholar 12K. Handique, D. T. Burke, C. H. Mastrangelo, M. A. Burns, Anal. Chem. 2001, 73, 1831. CrossrefCASPubMedWeb of Science®Google Scholar 13K. Hosokawa, T. Fujii, I. Endo, Anal. Chem. 1999, 71, 4781. CrossrefCASWeb of Science®Google Scholar 14P. J. A. Kenis, R. F. Ismagilov, G. M. Whitesides, Science 1999, 285, 83. CrossrefCASPubMedWeb of Science®Google Scholar 15J. E. Squires, Science 2002, 295, 1002. CrossrefCASPubMedWeb of Science®Google Scholar 16T. Thorsen, R. W. Roberts, F. H. Arnold, S. R. Quake, Phys. Rev. Lett. 2001, 86, 4163. CrossrefCASPubMedWeb of Science®Google Scholar 17S. Sugiura, M. Nakajima, M. Seki, Langmuir 2002, 18, 5708. CrossrefCASWeb of Science®Google Scholar 18The viscosity of PFD is 5.10×10−3 kg m−3 s−1, the surface tension at the interface between water and fluorinated phase was 13×10−3 N m−1. We have shown that this system can be operated at values of Ca up to about 0.1 (at 300 mm s−1). As the value of Ca increases above about 0.2, the formation of plugs becomes irregular. Google Scholar 19K. Handique, M. A. Burns, J. Micromech. Microeng. 2001, 11, 548. CrossrefCASWeb of Science®Google Scholar 20R. H. Liu, M. A. Stremler, K. V. Sharp, M. G. Olsen, J. G. Santiago, R. J. Adrian, H. Aref, D. J. Beebe, J. Microelectromech. Syst. 2000, 9, 190. CrossrefWeb of Science®Google Scholar 21J. M. Ottino, The Kinematics of Mixing: Stretching, Chaos, and Transport, Cambridge University Press, Cambridge, 1989. Google Scholar 22H. Aref, J. Fluid Mech. 1984, 143, 1. CrossrefWeb of Science®Google Scholar 23W. L. Chien, H. Rising, J. M. Ottino, J. Fluid Mech. 1986, 170, 355. CrossrefCASWeb of Science®Google Scholar 24S. C. Jana, G. Metcalfe, J. M. Ottino, J. Fluid Mech. 1994, 269, 199. CrossrefCASWeb of Science®Google Scholar 25T. H. Solomon, J. P. Gollub, Phys. Rev. A 1988, 38, 6280. CrossrefCASPubMedWeb of Science®Google Scholar 26M. Naraghi, Cell Calcium 1997, 22, 255. CrossrefCASPubMedWeb of Science®Google Scholar 27T. Thorsen, S. J. Maerkl, S. R. Quake, Science 2002, 298, 580. CrossrefCASPubMedWeb of Science®Google Scholar 28J. Eggers, J. R. Lister, H. A. Stone, J. Fluid Mech. 1999, 401, 293. CrossrefCASWeb of Science®Google Scholar 29H. Small, M. A. Langhorst, Anal. Chem. 1982, 54, A 892. CrossrefCASWeb of Science®Google Scholar 30M. A. Unger, H. P. Chou, T. Thorsen, A. Scherer, S. R. Quake, Science 2000, 288, 113. CrossrefCASPubMedWeb of Science®Google Scholar 31A. Arkin, P. D. Shen, J. Ross, Science 1997, 277, 1275. CrossrefCASWeb of Science®Google Scholar 32B. Zhao, N. O. L. Viernes, J. S. Moore, D. J. Beebe, J. Am. Chem. Soc. 2002, 124, 5284. CrossrefCASPubMedWeb of Science®Google Scholar 33M. Tokeshi, T. Minagawa, K. Uchiyama, A. Hibara, K. Sato, H. Hisamoto, T. Kitamori, Anal. Chem. 2002, 74, 1565. CrossrefCASPubMedWeb of Science®Google Scholar Citing Literature Volume42, Issue7February 17, 2003Pages 768-772 This article also appears in:Microfluidics FiguresReferencesRelatedInformation
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
DoubleW完成签到 ,获得积分10
25秒前
方方别方应助科研通管家采纳,获得10
38秒前
科目三应助长安采纳,获得10
49秒前
lzy完成签到,获得积分10
1分钟前
共享精神应助30采纳,获得10
1分钟前
忧虑的翠桃完成签到 ,获得积分10
2分钟前
2分钟前
2分钟前
2分钟前
长安发布了新的文献求助10
2分钟前
3分钟前
吴WU发布了新的文献求助10
3分钟前
3分钟前
tangyuan发布了新的文献求助10
3分钟前
StayGolDay完成签到,获得积分10
3分钟前
3分钟前
4分钟前
tangyuan完成签到,获得积分10
4分钟前
科研通AI2S应助科研通管家采纳,获得10
4分钟前
科研通AI2S应助科研通管家采纳,获得10
4分钟前
李健的小迷弟应助lve采纳,获得10
4分钟前
4分钟前
蛋蛋发布了新的文献求助10
5分钟前
5分钟前
活力青筠完成签到,获得积分10
5分钟前
lve发布了新的文献求助10
5分钟前
菲菲完成签到,获得积分10
5分钟前
菲菲发布了新的文献求助10
5分钟前
5分钟前
zcn123发布了新的文献求助10
5分钟前
orixero应助蛋蛋采纳,获得10
5分钟前
lve完成签到,获得积分10
6分钟前
6分钟前
科研通AI2S应助科研通管家采纳,获得10
6分钟前
方方别方应助科研通管家采纳,获得10
6分钟前
科目三应助科研通管家采纳,获得10
6分钟前
zcn123完成签到,获得积分10
7分钟前
8分钟前
NexusExplorer应助LHS采纳,获得10
8分钟前
蛋蛋发布了新的文献求助10
8分钟前
高分求助中
Production Logging: Theoretical and Interpretive Elements 2500
Востребованный временем 2500
Aspects of Babylonian celestial divination : the lunar eclipse tablets of enuma anu enlil 1500
Agaricales of New Zealand 1: Pluteaceae - Entolomataceae 1040
Healthcare Finance: Modern Financial Analysis for Accelerating Biomedical Innovation 1000
Classics in Total Synthesis IV: New Targets, Strategies, Methods 1000
体心立方金属铌、钽及其硼化物中滑移与孪生机制的研究 800
热门求助领域 (近24小时)
化学 医学 材料科学 生物 工程类 有机化学 生物化学 纳米技术 内科学 物理 化学工程 计算机科学 复合材料 基因 遗传学 物理化学 催化作用 细胞生物学 免疫学 电极
热门帖子
关注 科研通微信公众号,转发送积分 3450450
求助须知:如何正确求助?哪些是违规求助? 3045935
关于积分的说明 9003716
捐赠科研通 2734577
什么是DOI,文献DOI怎么找? 1500058
科研通“疑难数据库(出版商)”最低求助积分说明 693318
邀请新用户注册赠送积分活动 691462