Sobp公司
相对生物效应
布拉格峰
质子
线性能量转移
辐射敏感性
质子疗法
核医学
剂量学
梁(结构)
氧气增强率
化学
辐照
物理
光学
核物理学
医学
作者
Richard A. Britten,Vahagn Nazaryan,Leslie K. Davis,Susan Blakeley Klein,Dmitri Nichiporov,Marc S. Mendonca,M. Wolanski,Xiliang Nie,Jerry George,C. Keppel
出处
期刊:Radiation Research
[BioOne (Radiation Research Society)]
日期:2012-11-13
卷期号:179 (1): 21-28
被引量:125
摘要
Considerable evidence now exists to show that that the relative biological effectiveness (RBE) changes considerably along the proton depth-dose distribution, with progressively higher RBE values at the distal part of the modulated, or spread out Bragg peak (SOBP) and in the distal dose fall-off (DDF). However, the highly variable nature of the existing studies (with regards to cell lines, and to the physical properties and dosimetry of the various proton beams) precludes any consensus regarding the RBE weighting factor at any position in the depth-dose profile. We have thus conducted a systematic study on the variation in RBE for cell killing for two clinical modulated proton beams at Indiana University and have determined the relationship between the RBE and the dose-averaged linear energy transfer (LETd) of the protons at various positions along the depth-dose profiles. Clonogenic assays were performed on human Hep2 laryngeal cancer cells and V79 cells at various positions along the SOBPs of beams with incident energies of 87 and 200 MeV. There was a marked variation in the radiosensitivity of both cell lines along the SOBP depth-dose profile of the 87 MeV proton beam. Using Hep2 cells, the D0.1 isoeffect dose RBE values (normalized against 60Co) were 1.46 at the middle of SOBP, 2.1 at the distal end of the SOBP and 2.3 in the DDF. For V79 cells, the D0.1 isoeffect RBE for the 87 MEV beam were 1.23 for the proximal end of the SOBP: 1.46 for the distal SOBP and 1.78 for the DDF. Similar D0.1 isoeffect RBE values were found for Hep2 cells irradiated at various positions along the depth-dose profile of the 200 MeV beam. Our experimentally derived RBE values were significantly correlated (P = 0.001) with the mean LETd of the protons at the various depths, which confirmed that proton RBE is highly dependent on LETd. These in vitro data suggest that the RBE of the proton beam at certain depths is greater than 1.1, a value currently used in most treatment planning algorithms. Thus, the potential for increased cell killing and normal tissue damage in the distal regions of the proton SOBP may be greater than originally thought.
科研通智能强力驱动
Strongly Powered by AbleSci AI