活动记录
计时型
心理学
医学
物理疗法
昼夜节律
内科学
作者
Jakub Schneider,Eva Fárková,Eduard Bakštein
标识
DOI:10.1080/07420528.2021.1992418
摘要
In this work, we investigated the accuracy of chronotype estimation from actigraphy while evaluating the required recording length and stability over time. Chronotypes have an important role in chronobiological and sleep research. In outpatient studies, chronotypes are typically evaluated by questionnaires. Alternatively, actigraphy provides potential means for measuring chronotype characteristics objectively, which opens many applications in chronobiology research. However, studies providing objective, critical evaluation of agreement between questionnaire-based and actigraphy-based chronotypes are lacking. We recorded 3-months of actigraphy and collected Morningness-Eveningness Questionnaire (MEQ), and Munich Chronotype Questionnaire (MCTQ) results from 122 women. Regression models were applied to evaluate the questionnaire-based chronotypes scores using selected actigraphy features. Changes in predictive strength were evaluated based on actigraphy recordings of different duration. The actigraphy was significantly associated with the questionnaire-based chronotype, and the best single-feature-based models explained 37% of the variability (R2) for MEQ (p < .001), 47% for mid-sleep time MCTQ-MSFsc (p < .001), and 19% for social jetlag MCTQ-SJLrel (p < .001). Concerning stability in time, the Mid-sleep and Acrophase features showed high levels of stability (test-retest R ~ 0.8), and actigraphy-based MSFscacti and SJLrelacti showed high temporal variability (test-retest R ~ 0.45). Concerning required recording length, features estimated from recordings with 3-week and longer observation periods had sufficient predictive power on unseen data. Additionally, our data showed that the subjectively reported extremes of the MEQ, MCTQ-MSFsc, and MCTQ-SJLrel are commonly overestimated compared to objective activity peak and middle of sleep differences measured by actigraphy. Such difference may be associated with chronotype time-variation. As actigraphy is considered accurate in sleep-wake cycle detection, we conclude that actigraphy-based chronotyping is appropriate for large-scale studies, especially where higher temporal variability in chronotype is expected.
科研通智能强力驱动
Strongly Powered by AbleSci AI