聚吡咯
材料科学
体内
生物相容性
电极
生物医学工程
巨噬细胞极化
表面改性
植入
共价键
电化学
体外
生物物理学
化学
巨噬细胞
医学
生物化学
外科
有机化学
生物
物理化学
生物技术
冶金
作者
Sang‐Hun Lee,Sehyeon Park,Junggeon Park,Jae Young Lee
标识
DOI:10.1016/j.actbio.2023.06.042
摘要
Bioelectrodes are critical components of implantable electronic devices that enable precise electrical signal transmission in close contact with living tissues. However, their in vivo performance is often compromised by inflammatory tissue reactions mainly induced by macrophages. Hence, we aimed to develop implantable bioelectrodes with high performance and high biocompatibility by actively modulating the inflammatory response of macrophages. Consequently, we fabricated heparin-doped polypyrrole electrodes (PPy/Hep) and immobilized anti-inflammatory cytokines (interleukin-4 [IL-4]) via non-covalent interactions. IL-4 immobilization did not alter the electrochemical performance of the original PPy/Hep electrodes. In vitro primary macrophage culture revealed that IL-4-immobilized PPy/Hep electrodes induced anti-inflammatory polarization of macrophages, similar to the soluble IL-4 control. In vivo subcutaneous implantation indicated that IL-4 immobilization on PPy/Hep promoted the anti-inflammatory polarization of host macrophages and significantly mitigated scarring around the implanted electrodes. In addition, high-sensitivity electrocardiogram signals were recorded from the implanted IL-4-immobilized PPy/Hep electrodes and compared to bare gold and PPy/Hep electrodes, which were maintained for up to 15 days post-implantation. This simple and effective surface modification strategy for developing immune-compatible bioelectrodes will facilitate the development of various electronic medical devices that require high sensitivities and long-term stabilities. To fabricate highly immunocompatible conductive polymer-based implantable electrodes with high performance and stability in vivo, we introduced the anti-inflammatory activity to PPy/Hep electrodes by immobilizing IL-4 via non-covalent surface modification. IL-4-immobilized PPy/Hep could significantly mitigate inflammatory responses and scarring around implants by skewing macrophages to an anti-inflammatory phenotype. The IL-4-immobilized PPy/Hep electrodes could successfully record in vivo electrocardiogram signals for up to 15 days with no substantial sensitivity loss, retaining their superior sensitivity compared to bare gold and pristine PPy/Hep electrodes. Our simple and effective surface modification strategy for developing immune-compatible bioelectrodes will facilitate the development of various electronic medical devices that require high sensitivities and long-term stabilities, such as neural electrode arrays, biosensors, and cochlear electrodes.
科研通智能强力驱动
Strongly Powered by AbleSci AI