医学
内镜黏膜下剥离术
食管
外科
解剖(医学)
胃
不利影响
内科学
作者
Rui Ji,Jialin Yang,Xiaoxiao Yang,Shi-Chen Fu,Lixiang Li,Yanqing Li,Xiuli Zuo
标识
DOI:10.1016/j.gie.2022.01.004
摘要
Background and Aims Effective countertraction is a main challenging issue in endoscopic submucosal dissection (ESD). Several countertraction methods have been developed to address this issue. The aim of this study was to compare the efficacy of ESD using a novel simplified robot, the flexible auxiliary single-arm transluminal endoscopic robot (FASTER), with a traditional technique. Methods This was a prospective, randomized animal study. Forty-eight ESDs in 6 pigs were carried out at 8 different locations (gastric antrum, gastric body, lower esophagus, and middle esophagus) by the conventional method (n = 24) and by the FASTER-assisted method (n = 24). The primary outcomes were total procedure time, dissection time, and rate of direct-vision dissection. Secondary endpoints were completeness of en-bloc resection and adverse event rate. Results The total procedure time was significantly shorter in FASTER-assisted ESD than in conventional ESD (18.8 vs 32.8 minutes; P < .001). In contrast to the median direct-vision dissection rate of 73% with conventional ESD, the FASTER-assisted group had a significantly higher rate of 96% (P < .001). The number of sites of muscular damage was significantly lower using the FASTER-assisted method than the conventional method (6 vs 21, respectively; P = .018). This improvement was more apparent in esophageal lesions compared with gastric lesions. Conclusions This study demonstrated that using a simplified robot during ESD is technically feasible and enables the endoscopist to dynamically use countertraction. This device could significantly reduce procedure time compared with conventional ESD techniques. Effective countertraction is a main challenging issue in endoscopic submucosal dissection (ESD). Several countertraction methods have been developed to address this issue. The aim of this study was to compare the efficacy of ESD using a novel simplified robot, the flexible auxiliary single-arm transluminal endoscopic robot (FASTER), with a traditional technique. This was a prospective, randomized animal study. Forty-eight ESDs in 6 pigs were carried out at 8 different locations (gastric antrum, gastric body, lower esophagus, and middle esophagus) by the conventional method (n = 24) and by the FASTER-assisted method (n = 24). The primary outcomes were total procedure time, dissection time, and rate of direct-vision dissection. Secondary endpoints were completeness of en-bloc resection and adverse event rate. The total procedure time was significantly shorter in FASTER-assisted ESD than in conventional ESD (18.8 vs 32.8 minutes; P < .001). In contrast to the median direct-vision dissection rate of 73% with conventional ESD, the FASTER-assisted group had a significantly higher rate of 96% (P < .001). The number of sites of muscular damage was significantly lower using the FASTER-assisted method than the conventional method (6 vs 21, respectively; P = .018). This improvement was more apparent in esophageal lesions compared with gastric lesions. This study demonstrated that using a simplified robot during ESD is technically feasible and enables the endoscopist to dynamically use countertraction. This device could significantly reduce procedure time compared with conventional ESD techniques.
科研通智能强力驱动
Strongly Powered by AbleSci AI