医学
激光器
分级比例尺
Nd:YAG激光器
置信区间
外科
核医学
皮肤病科
光学
内科学
物理
作者
Mithila Vanarase,R. K. Gautam,Pooja Arora,Sonali Bajaj,Neha Meena,Ananta Khurana
标识
DOI:10.1080/14764172.2017.1314506
摘要
Background: Q-switched lasers are conventionally used for the treatment of black tattoo. However, they require multiple sittings, and the response may be slow due to competing epidermal pigment in dark skin. Objective: To compare the efficacy of Q-switched Nd:YAG laser alone with its combination with ultrapulse CO2 for the removal of black tattoo. Materials and methods: Sixty patients with black tattoo were randomized into two groups viz., group A and group B. Group A was treated with QS Nd:YAG laser (1064 nm) alone, and group B received combination of ablative ultrapulse CO2 followed by fixed-dose QS Nd:YAG laser (1064 nm), at 6-week interval for a maximum of 6 sittings. After each sitting, 3 independent physicians noted percentage of improvement that was evaluated using visual analogue scale (VAS) and grading system for tattoo ink lightening (TIL). Results: Combination laser (group B) showed statistically significant improvement in mean VAS score in the last 2 noted visits as compared to 1st session (p < 0.007, p < 0.001) and TIL mean score in last three noted visits as compared to 1st session (p < 0.008, p < 0.020, and p < 0.004). There was no statistically significant difference in the side effect profile of both the groups. Conclusion: For refractory professional tattoos, combination of ultrapulse CO2 laser and QS Nd:YAG laser is superior to QS Nd:YAG laser alone.
科研通智能强力驱动