化学
药代动力学
色谱法
生物利用度
选择性反应监测
液相色谱-质谱法
口服
检出限
串联质谱法
质谱法
药理学
医学
作者
D. N. Dai,Lixia Pei,Lin Tang,Feng Chen,Xiuping Chen
摘要
ABSTRACT A sensitive and rapid liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for determination of bakkenolide D (BD), which was further applied to assess the pharmacokinetics of BD. In the LC‐MS/MS method, the multiple reaction monitoring mode was used and columbianadin was chosen as internal standard. The method was validated over the range of 1–800 ng/mL with a determination coefficient >0.999. The lower limit of quantification was 1 ng/mL in plasma. The intra‐ and inter‐day accuracies for BD were 91–113 and 100–104%, respectively, and the inter‐day precision was <15%. After a single oral dose of 10 mg/kg of BD, the mean peak plasma concentration of BD was 10.1 ± 9.8 ng/mL at 2 h. The area under the plasma concentration–time curve (AUC 0–24 h ) was 72.1 ± 8.59 h ng/mL, and the elimination half‐life ( T 1/2 ) was 11.8 ± 1.9 h. In case of intravenous administration of BD at a dosage of 1 mg/kg, the AUC 0–24 h was 281 ± 98.4 h⋅ng/mL, and the T 1/2 was 8.79 ± 0.63 h. Based on these results, the oral bioavailability of BD in rats at 10 mg/kg is 2.57%. Copyright © 2013 John Wiley & Sons, Ltd.
科研通智能强力驱动
Strongly Powered by AbleSci AI