医学
呼气末正压
死区
功能剩余容量
麻醉
容积描记器
通风(建筑)
潮气量
肺容积
肺
机械通风
高碳酸血症
气道
心脏病学
气道阻塞
呼吸系统
内科学
机械工程
工程类
作者
Maria Paula Caramez,João Batista Borges,Mauro R. Tucci,Valdelis Novis Okamoto,Carlos Roberto Ribeiro de Carvalho,Robert M. Kacmarek,Atul Malhotra,Irineu Tadeu Velasco,Marcelo B. P. Amato
标识
DOI:10.1097/01.ccm.0000168044.98844.30
摘要
Objective: To reevaluate the clinical impact of external positive end-expiratory pressure (external-PEEP) application in patients with severe airway obstruction during controlled mechanical ventilation. The controversial occurrence of a paradoxic lung deflation promoted by PEEP was scrutinized. Design: External-PEEP was applied stepwise (2 cm H2O, 5-min steps) from zero-PEEP to 150% of intrinsic-PEEP in patients already submitted to ventilatory settings minimizing overinflation. Two commonly used frequencies during permissive hypercapnia (6 and 9/min), combined with two different tidal volumes (VT: 6 and 9 mL/kg), were tested. Setting: A hospital intensive care unit. Patients: Eight patients were enrolled after confirmation of an obstructive lung disease (inspiratory resistance, >20 cm H2O/L per sec) and the presence of intrinsic-PEEP (≥5 cm H2O) despite the use of very low minute ventilation. Interventions: All patients were continuously monitored for intra-arterial blood gas values, cardiac output, lung mechanics, and lung volume with plethysmography. Measurements and Main Results: Three different responses to external-PEEP were observed, which were independent of ventilatory settings. In the biphasic response, isovolume-expiratory flows and lung volumes remained constant during progressive PEEP steps until a threshold, beyond which overinflation ensued. In the classic overinflation response, any increment of external-PEEP caused a decrease in isovolume-expiratory flows, with evident overinflation. In the paradoxic response, a drop in functional residual capacity during external-PEEP application (when compared to zero-external-PEEP) was commonly accompanied by decreased plateau pressures and total-PEEP, with increased isovolume-expiratory flows. The paradoxic response was observed in five of the eight patients (three with asthma and two with chronic obstructive pulmonary disease) during at least one ventilator pattern. Conclusions: External-PEEP application may relieve overinflation in selected patients with airway obstruction during controlled mechanical ventilation. No a priori information about disease, mechanics, or ventilatory settings was predictive of the response. An empirical PEEP trial investigating plateau pressure response in these patients appears to be a reasonable strategy with minimal side effects.
科研通智能强力驱动
Strongly Powered by AbleSci AI