应力腐蚀开裂
压水堆
材料科学
合金
极限抗拉强度
冷却液
冶金
腐蚀
开裂
张力(地质)
断裂力学
下降(电信)
复合材料
核工程
电信
核物理学
工程类
物理
计算机科学
作者
Ziqing Zhai,Ferdinan Cintron-Colon,R. Bouffioux,Mychailo B. Toloczko
出处
期刊:Corrosion
[NACE International]
日期:2024-01-16
摘要
ABSTRACT The stress corrosion cracking behavior of high-strength Ni-base Alloy X-750 and Alloy 718 has been investigated to assess the effect of replacing LiOH with KOH as the pH moderator in pressurized water reactor (PWR) primary circuit coolant. The SCC initiation behavior of X-750 was evaluated by multi-tensile specimen constant load test in either LiOH- or KOH- containing PWR primary water. The SCC growth behavior of X-750 and Alloy 718 was evaluated on compact tension specimens with on-the-fly changes between LiOH- and KOH-containing water in three different PWR primary water chemistries. Direct current potential drop technique was used for in-situ monitoring of crack initiation time and crack extension in SCC initiation and propagation tests, respectively. The results suggest no significant effect of KOH vs. LiOH on the SCC initiation or propagation of the tested materials.