运动学
生物力学
膝关节
步态
膝关节屈曲
磁共振成像
步态分析
医学
生物医学工程
口腔正畸科
物理医学与康复
解剖
物理
外科
放射科
经典力学
作者
Wenjin Wang,Tsung-Yuan Tsai,Cui Zhang,Jinpeng Lin,Wei Dai,Ming Zhang,Wolfgang Potthast,Yu Liu,Shaobai Wang
标识
DOI:10.1016/j.gaitpost.2022.07.008
摘要
Accurate measurements of in-vivo knee joint kinematics are essential to elucidate healthy knee motion and the changes that accompany injury and repair. Although numerous experimental measurements have been reported, the accurate non-invasive analysis of in-vivo knee kinematics remains a challenge in biomechanics.The study objective was to investigate in-vivo knee kinematics before, at, and after contact during walking and running using a combined high-speed dual fluoroscopic imaging system (DFIS) and magnetic resonance (MR) imaging technique.Three-dimensional (3D) knee models of ten participants were created using MR images. Knee kinematics during walking and running were determined using high-speed DFIS. The 3D knee models were then related to fluoroscopic images to obtain in-vivo six-degrees-of-freedom knee kinematics.Before contact knee flexion, external femoral rotation, and proximal-distal distance were 11.9°, 3.4°, and 1.0 mm greater during running compared to walking, respectively. Similar differences were observed at initial contact (9.9°, 7.9°, and 0.9 mm, respectively) and after contact (6.4°, 2.2°, and 0.8 mm, respectively). Posterior femoral translation at initial contact was also increased during running compared to walking.This study demonstrated accurate instantaneous in-vivo knee kinematic characteristics that may further the understanding of the intrinsic biomechanics of the knee during gait.