医学
冲程(发动机)
磁共振成像
心脏病学
病变
接收机工作特性
内科学
阀门更换
磁共振弥散成像
冲程容积
梗塞
核医学
放射科
心肌梗塞
外科
射血分数
心力衰竭
工程类
机械工程
狭窄
作者
Alexandra J. Lansky,Daniel Grubman,Michael G. Dwyer,Robert Zivadinov,Helen Parise,Jeffrey W. Moses,Tayyab Shah,Cody Pietras,Daniela Tı̂rziu,Louise Gambone,Martin B. Leon,Tamim Nazif,Steven R. Messé
标识
DOI:10.1016/j.jacc.2024.05.055
摘要
Acute brain infarction detected by diffusion-weighted magnetic resonance imaging (DW-MRI) is common after transcatheter aortic valve replacement (TAVR), but its clinical relevance is uncertain. The authors investigated the relationship between DW-MRI total lesion number (TLN), individual lesion volume (ILV), and total lesion volume (TLV) and clinical stroke outcomes after TAVR. Patient-level data were pooled from 4 prospective TAVR embolic protection studies, with consistent predischarge DW-MRI acquisition and core laboratory analysis. C-statistic was used to determine the best DW-MRI measure associated with clinical stroke. A total of 495 of 603 patients undergoing TAVR completed the predischarge DW-MRI. At 30 days, the rate of clinical ischemic stroke was 6.9%. Acute ischemic brain injury was seen in 85% of patients with 5.5 ± 7.3 discrete lesions per patient, mean ILV of 78.2 ± 257.1 mm3, and mean TLV of 555 ± 1,039 mm3. The C-statistic was 0.84 for TLV, 0.81 for number of lesions, and 0.82 for maximum ILV in predicting ischemic stroke. On the basis of the TLV cutpoint as defined by receiver operating characteristic (ROC), patients with a TLV >500 mm3 (vs TLV ≤500 mm3) had more ischemic stroke (18.2% vs 2.3%; P < 0.0001), more disabling strokes (8.8% vs 0.9%; P < 0.0001), and less complete stroke recovery (44% vs 62.5%; P = 0.001) at 30 days. Our study confirms that the number, size, and total volume of acute brain infarction defined by DW-MRI are each associated with clinical ischemic strokes, disabling strokes, and worse stroke recovery in patients undergoing TAVR and may have value as surrogate outcomes in stroke prevention trials. (A Prospective, Randomized Evaluation of the TriGuard™ HDH Embolic Deflection Device During TAVI [DEFLECT III]; NCT02070731) (A Study to Evaluate the Neuro-embolic Consequences of TAVR [NeuroTAVR]; NCT02073864) (The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation [REFLECT I]; NCT02536196) (The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation [REFLECT II]; NCT02536196)
科研通智能强力驱动
Strongly Powered by AbleSci AI